Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects

Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatrics (Evanston) 2006-01, Vol.117 (1), p.e16-e21
Hauptverfasser: O'Donnell, Colm P.F, Kamlin, C. Omar F, Davis, Peter G, Morley, Colin J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e21
container_issue 1
container_start_page e16
container_title Pediatrics (Evanston)
container_volume 117
creator O'Donnell, Colm P.F
Kamlin, C. Omar F
Davis, Peter G
Morley, Colin J
description Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by > or =10% during the attempt and, if so, at what time it occurred. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%,
doi_str_mv 10.1542/peds.2005-0901
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1542_peds_2005_0901</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16396845</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-27e315a97a3082bccd7f006369d3593368fffe2f5788d95dca94d85df5c932763</originalsourceid><addsrcrecordid>eNpNkM1OAjEYRRujEUS3Lk0fgMH-TKdTdwRRSYgmqOum9AdqYIa0HY1v7wyQ4Or7knvuXRwAbjEaYZaT-501cUQQYhkSCJ-BPkaizHLC2TnoI0RxlrdhD1zF-IUQyhknl6CHCyqKMmd9sJlWpk5B6bVVGzirUrNUydcVHKdkt7sU4WMTfLWCr7auVGqZhY1N1D7tsQf43mhtY4QLlWwcdvQ-GEJVGTg23zZEC6fOWZ3iNbhwahPtzfEOwOfT9GPyks3fnmeT8TzTtOApI9xSzJTgiqKSLLU23CFU0EIYygSlRenaPeIYL0sjmNFK5KZkxjEtKOEFHYDRYVeHOsZgndwFv1XhV2IkO22y0yY7bbLT1hbuDoVds9xac8KPnk6La79a__hguwWvUvA6_nsx5hJL29b-ABiEewU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>O'Donnell, Colm P.F ; Kamlin, C. Omar F ; Davis, Peter G ; Morley, Colin J</creator><creatorcontrib>O'Donnell, Colm P.F ; Kamlin, C. Omar F ; Davis, Peter G ; Morley, Colin J</creatorcontrib><description>Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by &gt; or =10% during the attempt and, if so, at what time it occurred. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and Spo2 were low before the attempt. Intubation attempts often are unsuccessful, and successful attempts frequently take &gt;30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.</description><identifier>ISSN: 0031-4005</identifier><identifier>EISSN: 1098-4275</identifier><identifier>DOI: 10.1542/peds.2005-0901</identifier><identifier>PMID: 16396845</identifier><language>eng</language><publisher>United States: Am Acad Pediatrics</publisher><subject>Clinical Competence ; Delivery Rooms ; Humans ; Infant, Newborn ; Intubation, Intratracheal - adverse effects ; Positive-Pressure Respiration ; Resuscitation</subject><ispartof>Pediatrics (Evanston), 2006-01, Vol.117 (1), p.e16-e21</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-27e315a97a3082bccd7f006369d3593368fffe2f5788d95dca94d85df5c932763</citedby><cites>FETCH-LOGICAL-c367t-27e315a97a3082bccd7f006369d3593368fffe2f5788d95dca94d85df5c932763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16396845$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>O'Donnell, Colm P.F</creatorcontrib><creatorcontrib>Kamlin, C. Omar F</creatorcontrib><creatorcontrib>Davis, Peter G</creatorcontrib><creatorcontrib>Morley, Colin J</creatorcontrib><title>Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects</title><title>Pediatrics (Evanston)</title><addtitle>Pediatrics</addtitle><description>Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by &gt; or =10% during the attempt and, if so, at what time it occurred. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and Spo2 were low before the attempt. Intubation attempts often are unsuccessful, and successful attempts frequently take &gt;30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.</description><subject>Clinical Competence</subject><subject>Delivery Rooms</subject><subject>Humans</subject><subject>Infant, Newborn</subject><subject>Intubation, Intratracheal - adverse effects</subject><subject>Positive-Pressure Respiration</subject><subject>Resuscitation</subject><issn>0031-4005</issn><issn>1098-4275</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkM1OAjEYRRujEUS3Lk0fgMH-TKdTdwRRSYgmqOum9AdqYIa0HY1v7wyQ4Or7knvuXRwAbjEaYZaT-501cUQQYhkSCJ-BPkaizHLC2TnoI0RxlrdhD1zF-IUQyhknl6CHCyqKMmd9sJlWpk5B6bVVGzirUrNUydcVHKdkt7sU4WMTfLWCr7auVGqZhY1N1D7tsQf43mhtY4QLlWwcdvQ-GEJVGTg23zZEC6fOWZ3iNbhwahPtzfEOwOfT9GPyks3fnmeT8TzTtOApI9xSzJTgiqKSLLU23CFU0EIYygSlRenaPeIYL0sjmNFK5KZkxjEtKOEFHYDRYVeHOsZgndwFv1XhV2IkO22y0yY7bbLT1hbuDoVds9xac8KPnk6La79a__hguwWvUvA6_nsx5hJL29b-ABiEewU</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>O'Donnell, Colm P.F</creator><creator>Kamlin, C. Omar F</creator><creator>Davis, Peter G</creator><creator>Morley, Colin J</creator><general>Am Acad Pediatrics</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20060101</creationdate><title>Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects</title><author>O'Donnell, Colm P.F ; Kamlin, C. Omar F ; Davis, Peter G ; Morley, Colin J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-27e315a97a3082bccd7f006369d3593368fffe2f5788d95dca94d85df5c932763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Clinical Competence</topic><topic>Delivery Rooms</topic><topic>Humans</topic><topic>Infant, Newborn</topic><topic>Intubation, Intratracheal - adverse effects</topic><topic>Positive-Pressure Respiration</topic><topic>Resuscitation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>O'Donnell, Colm P.F</creatorcontrib><creatorcontrib>Kamlin, C. Omar F</creatorcontrib><creatorcontrib>Davis, Peter G</creatorcontrib><creatorcontrib>Morley, Colin J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Pediatrics (Evanston)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>O'Donnell, Colm P.F</au><au>Kamlin, C. Omar F</au><au>Davis, Peter G</au><au>Morley, Colin J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects</atitle><jtitle>Pediatrics (Evanston)</jtitle><addtitle>Pediatrics</addtitle><date>2006-01-01</date><risdate>2006</risdate><volume>117</volume><issue>1</issue><spage>e16</spage><epage>e21</epage><pages>e16-e21</pages><issn>0031-4005</issn><eissn>1098-4275</eissn><abstract>Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by &gt; or =10% during the attempt and, if so, at what time it occurred. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and Spo2 were low before the attempt. Intubation attempts often are unsuccessful, and successful attempts frequently take &gt;30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.</abstract><cop>United States</cop><pub>Am Acad Pediatrics</pub><pmid>16396845</pmid><doi>10.1542/peds.2005-0901</doi></addata></record>
fulltext fulltext
identifier ISSN: 0031-4005
ispartof Pediatrics (Evanston), 2006-01, Vol.117 (1), p.e16-e21
issn 0031-4005
1098-4275
language eng
recordid cdi_crossref_primary_10_1542_peds_2005_0901
source MEDLINE; EZB-FREE-00999 freely available EZB journals
subjects Clinical Competence
Delivery Rooms
Humans
Infant, Newborn
Intubation, Intratracheal - adverse effects
Positive-Pressure Respiration
Resuscitation
title Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T17%3A07%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endotracheal%20Intubation%20Attempts%20During%20Neonatal%20Resuscitation:%20Success%20Rates,%20Duration,%20and%20Adverse%20Effects&rft.jtitle=Pediatrics%20(Evanston)&rft.au=O'Donnell,%20Colm%20P.F&rft.date=2006-01-01&rft.volume=117&rft.issue=1&rft.spage=e16&rft.epage=e21&rft.pages=e16-e21&rft.issn=0031-4005&rft.eissn=1098-4275&rft_id=info:doi/10.1542/peds.2005-0901&rft_dat=%3Cpubmed_cross%3E16396845%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/16396845&rfr_iscdi=true