Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects
Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and...
Gespeichert in:
Veröffentlicht in: | Pediatrics (Evanston) 2006-01, Vol.117 (1), p.e16-e21 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred.
We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by > or =10% during the attempt and, if so, at what time it occurred.
We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, |
---|---|
ISSN: | 0031-4005 1098-4275 |