Mechanical Characteristics of an XLPE Cable and a Joint under High Temperature
Characteristics of crosslinked polyethylene used in XLPE cable change much over 100°C. Mechanical characteristics of crosslinked polyethylene insulated cables and tape lapped joints under high temperature condition were studied. A cleat doesn't change shape of a cable and short-circuit current...
Gespeichert in:
Veröffentlicht in: | Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku 2001/01/01, Vol.121(1), pp.115-122 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Characteristics of crosslinked polyethylene used in XLPE cable change much over 100°C. Mechanical characteristics of crosslinked polyethylene insulated cables and tape lapped joints under high temperature condition were studied. A cleat doesn't change shape of a cable and short-circuit current and ground fault current don't damage a cable at about 105°C. On the other hand, at about 105°C, performance of water impervious layer degraded. Copper taps lapped shield are broken at an offset position with thermal expansion and contraction. Support force of a cleat decreases and lead tape lapped shield is broken. |
---|---|
ISSN: | 0385-4213 1348-8147 |
DOI: | 10.1541/ieejpes1990.121.1_115 |