Effect of Internal Baffle on Desulfurization Efficiency in Fluidized Bed Coal Combustor

Combustion tests using Datung-coal were carried out in an experimental fluidized-bed combustor with a grid-type internal baffle. Effects of the baffle on combustion characteristics, especially in desulfurization efficiency, were investigated. The combustor was 0.155 m in I.D. Static bed heigh was 0....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:KAGAKU KOGAKU RONBUNSHU 1987/11/10, Vol.13(6), pp.721-727
Hauptverfasser: Yoshioka, Susumu, Murakami, Tadayoshi, Ohki, Katsuya, Nonaka, Kimihiro
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Combustion tests using Datung-coal were carried out in an experimental fluidized-bed combustor with a grid-type internal baffle. Effects of the baffle on combustion characteristics, especially in desulfurization efficiency, were investigated. The combustor was 0.155 m in I.D. Static bed heigh was 0.4 m. The baffle was placed 0.45 m above the air distributor. The installation of the baffle markedly improved the desulfurization efficiency. The oxygen concentration in the bed below the baffle was found to increase. It was concluded that the improvement in desulfurization efficiency resulted from the faster sulfation rate of CaO in the more oxidative atmosphere.
ISSN:0386-216X
1349-9203