SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE
Sensitivity in electron microscope autoradiography using Ilford L4 emulsion was shown to be affected by radiation dose (i.e., number of decays in test specimen per unit surface area). The sensitivity tended to be higher with lower doses. This dose dependence was most marked with Microdol X and least...
Gespeichert in:
Veröffentlicht in: | J. Histochem. Cytochem. 20: No. 6, 425-34(1972) 425-34(1972), 1972-06, Vol.20 (6), p.425-434 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 434 |
---|---|
container_issue | 6 |
container_start_page | 425 |
container_title | J. Histochem. Cytochem. 20: No. 6, 425-34(1972) |
container_volume | 20 |
creator | SALPETER, MIRIAM M SZABO, MARIA |
description | Sensitivity in electron microscope autoradiography using Ilford L4 emulsion was shown to be affected by radiation dose (i.e., number of decays in test specimen per unit surface area). The sensitivity tended to be higher with lower doses. This dose dependence was most marked with Microdol X and least with gold latensification-Elon ascorbic acid development. Possible consequences for quantitation in electron microscope autoradiography are discussed. |
doi_str_mv | 10.1177/20.6.425 |
format | Article |
fullrecord | <record><control><sourceid>sage_osti_</sourceid><recordid>TN_cdi_crossref_primary_10_1177_20_6_425</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_20.6.425</sage_id><sourcerecordid>10.1177_20.6.425</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3145-2c9571b0abbd2309d53a0fdaf2861208c9953639bd4d8611d62d2295a09bb1d93</originalsourceid><addsrcrecordid>eNptkFFrgzAUhcPY6LpusD8wkMFgL7okGm0exWordE1RO9hTiEZbR1uLaZH9-6VY-rSnC-d898A5ADwjaCHkeR8YWq7lYHIDhogQZBLoOLdgCCHGphace_Cg1A-EyHHIeAAGBNqYenQIkjRcpHEWf8XZtxEvjHAeBlnCFsZnHCQsDdgyNPxVxhJ_ErNp4i9nGrOMbBYaYRRp1mCRcTb9LNZfE5aGj-CuEltVPl3uCKyiMAtm5pxN48Cfm4WNHGLighIP5VDkucQ2pJLYAlZSVHjsIgzHBaXEdm2aS0dqBUkXS4wpEZDmOZLUHoHXPrdRx5qroj6WxaZo9vuyOHJd0yUu1tB7DxVto1RbVvzQ1jvR_nIE-Xk6jiF3uZ5Ooy89ejjlu1JewctW2n_rfSXWJf9pTu1e1_sv58Jt6vWmq9uSq53YbnUq4l3XXbk_5bJ30A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>SAGE Complete A-Z List</source><source>Free Full-Text Journals in Chemistry</source><creator>SALPETER, MIRIAM M ; SZABO, MARIA</creator><creatorcontrib>SALPETER, MIRIAM M ; SZABO, MARIA ; Cornell Univ., Ithaca, N. Y</creatorcontrib><description>Sensitivity in electron microscope autoradiography using Ilford L4 emulsion was shown to be affected by radiation dose (i.e., number of decays in test specimen per unit surface area). The sensitivity tended to be higher with lower doses. This dose dependence was most marked with Microdol X and least with gold latensification-Elon ascorbic acid development. Possible consequences for quantitation in electron microscope autoradiography are discussed.</description><identifier>ISSN: 0022-1554</identifier><identifier>EISSN: 1551-5044</identifier><identifier>DOI: 10.1177/20.6.425</identifier><identifier>PMID: 5032979</identifier><language>eng</language><publisher>London, England: Histochemical Soc</publisher><subject>Absorption ; Acrylic Resins ; Ascorbic Acid ; AUTORADIOGRAPHY ; AUTORADIOGRAPHY/sensitivity of electron microscope, effect of radiation dose on ; CALIBRATION ; CALIBRATION STANDARDS ; DEVELOPERS ; DOSE- RESPONSE RELATIONSHIPS ; ELECTRON MICROSCOPES ; ELECTRON MICROSCOPES/calibration procedures for autoradiography ; Emulsions ; Gold ; Methods ; Microscopy, Electron ; N46110 -Instrumentation-Radiation Detection Instruments- General Detectors & Monitors ; NUCLEAR EMULSIONS ; NUCLEAR EMULSIONS/sensitivity of Ilford L4, effect of developer on dose dependence of ; Phenols ; PHOTOGRAPHIC FILMS ; PHOTOGRAPHY ; Radiation Dosage ; SENSITIVITY ; Sulfites ; Thiocyanates ; Tritium</subject><ispartof>J. Histochem. Cytochem. 20: No. 6, 425-34(1972), 1972-06, Vol.20 (6), p.425-434</ispartof><rights>1972, THE HISTOCHEMICAL SOCIETY, INC.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3145-2c9571b0abbd2309d53a0fdaf2861208c9953639bd4d8611d62d2295a09bb1d93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/20.6.425$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/20.6.425$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,885,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/5032979$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/4586562$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>SALPETER, MIRIAM M</creatorcontrib><creatorcontrib>SZABO, MARIA</creatorcontrib><creatorcontrib>Cornell Univ., Ithaca, N. Y</creatorcontrib><title>SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE</title><title>J. Histochem. Cytochem. 20: No. 6, 425-34(1972)</title><addtitle>J. Histochem. Cytochem</addtitle><description>Sensitivity in electron microscope autoradiography using Ilford L4 emulsion was shown to be affected by radiation dose (i.e., number of decays in test specimen per unit surface area). The sensitivity tended to be higher with lower doses. This dose dependence was most marked with Microdol X and least with gold latensification-Elon ascorbic acid development. Possible consequences for quantitation in electron microscope autoradiography are discussed.</description><subject>Absorption</subject><subject>Acrylic Resins</subject><subject>Ascorbic Acid</subject><subject>AUTORADIOGRAPHY</subject><subject>AUTORADIOGRAPHY/sensitivity of electron microscope, effect of radiation dose on</subject><subject>CALIBRATION</subject><subject>CALIBRATION STANDARDS</subject><subject>DEVELOPERS</subject><subject>DOSE- RESPONSE RELATIONSHIPS</subject><subject>ELECTRON MICROSCOPES</subject><subject>ELECTRON MICROSCOPES/calibration procedures for autoradiography</subject><subject>Emulsions</subject><subject>Gold</subject><subject>Methods</subject><subject>Microscopy, Electron</subject><subject>N46110 -Instrumentation-Radiation Detection Instruments- General Detectors & Monitors</subject><subject>NUCLEAR EMULSIONS</subject><subject>NUCLEAR EMULSIONS/sensitivity of Ilford L4, effect of developer on dose dependence of</subject><subject>Phenols</subject><subject>PHOTOGRAPHIC FILMS</subject><subject>PHOTOGRAPHY</subject><subject>Radiation Dosage</subject><subject>SENSITIVITY</subject><subject>Sulfites</subject><subject>Thiocyanates</subject><subject>Tritium</subject><issn>0022-1554</issn><issn>1551-5044</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1972</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkFFrgzAUhcPY6LpusD8wkMFgL7okGm0exWordE1RO9hTiEZbR1uLaZH9-6VY-rSnC-d898A5ADwjaCHkeR8YWq7lYHIDhogQZBLoOLdgCCHGphace_Cg1A-EyHHIeAAGBNqYenQIkjRcpHEWf8XZtxEvjHAeBlnCFsZnHCQsDdgyNPxVxhJ_ErNp4i9nGrOMbBYaYRRp1mCRcTb9LNZfE5aGj-CuEltVPl3uCKyiMAtm5pxN48Cfm4WNHGLighIP5VDkucQ2pJLYAlZSVHjsIgzHBaXEdm2aS0dqBUkXS4wpEZDmOZLUHoHXPrdRx5qroj6WxaZo9vuyOHJd0yUu1tB7DxVto1RbVvzQ1jvR_nIE-Xk6jiF3uZ5Ooy89ejjlu1JewctW2n_rfSXWJf9pTu1e1_sv58Jt6vWmq9uSq53YbnUq4l3XXbk_5bJ30A</recordid><startdate>197206</startdate><enddate>197206</enddate><creator>SALPETER, MIRIAM M</creator><creator>SZABO, MARIA</creator><general>Histochemical Soc</general><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>197206</creationdate><title>SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE</title><author>SALPETER, MIRIAM M ; SZABO, MARIA</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3145-2c9571b0abbd2309d53a0fdaf2861208c9953639bd4d8611d62d2295a09bb1d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1972</creationdate><topic>Absorption</topic><topic>Acrylic Resins</topic><topic>Ascorbic Acid</topic><topic>AUTORADIOGRAPHY</topic><topic>AUTORADIOGRAPHY/sensitivity of electron microscope, effect of radiation dose on</topic><topic>CALIBRATION</topic><topic>CALIBRATION STANDARDS</topic><topic>DEVELOPERS</topic><topic>DOSE- RESPONSE RELATIONSHIPS</topic><topic>ELECTRON MICROSCOPES</topic><topic>ELECTRON MICROSCOPES/calibration procedures for autoradiography</topic><topic>Emulsions</topic><topic>Gold</topic><topic>Methods</topic><topic>Microscopy, Electron</topic><topic>N46110 -Instrumentation-Radiation Detection Instruments- General Detectors & Monitors</topic><topic>NUCLEAR EMULSIONS</topic><topic>NUCLEAR EMULSIONS/sensitivity of Ilford L4, effect of developer on dose dependence of</topic><topic>Phenols</topic><topic>PHOTOGRAPHIC FILMS</topic><topic>PHOTOGRAPHY</topic><topic>Radiation Dosage</topic><topic>SENSITIVITY</topic><topic>Sulfites</topic><topic>Thiocyanates</topic><topic>Tritium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SALPETER, MIRIAM M</creatorcontrib><creatorcontrib>SZABO, MARIA</creatorcontrib><creatorcontrib>Cornell Univ., Ithaca, N. Y</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>J. Histochem. Cytochem. 20: No. 6, 425-34(1972)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SALPETER, MIRIAM M</au><au>SZABO, MARIA</au><aucorp>Cornell Univ., Ithaca, N. Y</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE</atitle><jtitle>J. Histochem. Cytochem. 20: No. 6, 425-34(1972)</jtitle><addtitle>J. Histochem. Cytochem</addtitle><date>1972-06</date><risdate>1972</risdate><volume>20</volume><issue>6</issue><spage>425</spage><epage>434</epage><pages>425-434</pages><issn>0022-1554</issn><eissn>1551-5044</eissn><abstract>Sensitivity in electron microscope autoradiography using Ilford L4 emulsion was shown to be affected by radiation dose (i.e., number of decays in test specimen per unit surface area). The sensitivity tended to be higher with lower doses. This dose dependence was most marked with Microdol X and least with gold latensification-Elon ascorbic acid development. Possible consequences for quantitation in electron microscope autoradiography are discussed.</abstract><cop>London, England</cop><pub>Histochemical Soc</pub><pmid>5032979</pmid><doi>10.1177/20.6.425</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-1554 |
ispartof | J. Histochem. Cytochem. 20: No. 6, 425-34(1972), 1972-06, Vol.20 (6), p.425-434 |
issn | 0022-1554 1551-5044 |
language | eng |
recordid | cdi_crossref_primary_10_1177_20_6_425 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; SAGE Complete A-Z List; Free Full-Text Journals in Chemistry |
subjects | Absorption Acrylic Resins Ascorbic Acid AUTORADIOGRAPHY AUTORADIOGRAPHY/sensitivity of electron microscope, effect of radiation dose on CALIBRATION CALIBRATION STANDARDS DEVELOPERS DOSE- RESPONSE RELATIONSHIPS ELECTRON MICROSCOPES ELECTRON MICROSCOPES/calibration procedures for autoradiography Emulsions Gold Methods Microscopy, Electron N46110 -Instrumentation-Radiation Detection Instruments- General Detectors & Monitors NUCLEAR EMULSIONS NUCLEAR EMULSIONS/sensitivity of Ilford L4, effect of developer on dose dependence of Phenols PHOTOGRAPHIC FILMS PHOTOGRAPHY Radiation Dosage SENSITIVITY Sulfites Thiocyanates Tritium |
title | SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY I. THE EFFECT OF RADIATION DOSE |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A05%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SENSITIVITY%20IN%20ELECTRON%20MICROSCOPE%20AUTORADIOGRAPHY%20I.%20THE%20EFFECT%20OF%20RADIATION%20DOSE&rft.jtitle=J.%20Histochem.%20Cytochem.%2020:%20No.%206,%20425-34(1972)&rft.au=SALPETER,%20MIRIAM%20M&rft.aucorp=Cornell%20Univ.,%20Ithaca,%20N.%20Y&rft.date=1972-06&rft.volume=20&rft.issue=6&rft.spage=425&rft.epage=434&rft.pages=425-434&rft.issn=0022-1554&rft.eissn=1551-5044&rft_id=info:doi/10.1177/20.6.425&rft_dat=%3Csage_osti_%3E10.1177_20.6.425%3C/sage_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/5032979&rft_sage_id=10.1177_20.6.425&rfr_iscdi=true |