Computer Modelling of Heat Transfer through Rigid Polyurethane Foam
In order to meet new demands for reduction in energy consumption for the appliance and building applications, there is an urgent need for the develop ment of rigid closed celled polyurethane foams with improved insulation properties. Furthermore, in view of the fact that chlorofluorocarbons (CFCs) h...
Gespeichert in:
Veröffentlicht in: | Journal of thermal envelope & building science 1990-07, Vol.14 (1), p.81-92 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 92 |
---|---|
container_issue | 1 |
container_start_page | 81 |
container_title | Journal of thermal envelope & building science |
container_volume | 14 |
creator | Smits, G.F. Thoen, J.A. |
description | In order to meet new demands for reduction in energy consumption for the appliance and building applications, there is an urgent need for the develop ment of rigid closed celled polyurethane foams with improved insulation properties. Furthermore, in view of the fact that chlorofluorocarbons (CFCs) have been iden tified as important potential contributors to the processes which cause a depletion of the ozone layer, there is, at the same time, a strong need to find viable alternatives to the use of CFCs, e.g., Freon™* -11 as blowing agents. |
doi_str_mv | 10.1177/109719639001400108 |
format | Article |
fullrecord | <record><control><sourceid>sage_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1177_109719639001400108</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_109719639001400108</sage_id><sourcerecordid>10.1177_109719639001400108</sourcerecordid><originalsourceid>FETCH-LOGICAL-c202t-889a8b161866496137303bc57eb6cb941f4fe8db85fae3cc25f2cda63c2411d63</originalsourceid><addsrcrecordid>eNp9j0FLxDAUhHNQcF39A57yB-rmJWmaHKW4rrCiyHouaZq0XdpmSdrD_ntb1tuCh-HBDN9jBqEnIM8AWbYBojJQgilCgM8i8gatFjNZ3Dt0H-OREApcyBXKc9-fptEG_OEr23XtUGPv8M7qER-CHqKbo7EJfqob_N3WbYW_fHeegh0bPVi89bp_QLdOd9E-_t01-tm-HvJdsv98e89f9omhhI6JlErLEgRIIbgSwDJGWGnSzJbClIqD487KqpSp05YZQ1NHTaUFM5QDVIKtEb38NcHHGKwrTqHtdTgXQIplenE9fYY2Fyjq2hZHP4Vh7vgf8Qsqnlr0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Computer Modelling of Heat Transfer through Rigid Polyurethane Foam</title><source>Access via SAGE</source><source>Alma/SFX Local Collection</source><creator>Smits, G.F. ; Thoen, J.A.</creator><creatorcontrib>Smits, G.F. ; Thoen, J.A.</creatorcontrib><description>In order to meet new demands for reduction in energy consumption for the appliance and building applications, there is an urgent need for the develop ment of rigid closed celled polyurethane foams with improved insulation properties. Furthermore, in view of the fact that chlorofluorocarbons (CFCs) have been iden tified as important potential contributors to the processes which cause a depletion of the ozone layer, there is, at the same time, a strong need to find viable alternatives to the use of CFCs, e.g., Freon™* -11 as blowing agents.</description><identifier>ISSN: 1097-1963</identifier><identifier>ISSN: 0148-8287</identifier><identifier>DOI: 10.1177/109719639001400108</identifier><language>eng</language><publisher>Thousand Oaks, CA: Sage Publications</publisher><ispartof>Journal of thermal envelope & building science, 1990-07, Vol.14 (1), p.81-92</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c202t-889a8b161866496137303bc57eb6cb941f4fe8db85fae3cc25f2cda63c2411d63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/109719639001400108$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/109719639001400108$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Smits, G.F.</creatorcontrib><creatorcontrib>Thoen, J.A.</creatorcontrib><title>Computer Modelling of Heat Transfer through Rigid Polyurethane Foam</title><title>Journal of thermal envelope & building science</title><description>In order to meet new demands for reduction in energy consumption for the appliance and building applications, there is an urgent need for the develop ment of rigid closed celled polyurethane foams with improved insulation properties. Furthermore, in view of the fact that chlorofluorocarbons (CFCs) have been iden tified as important potential contributors to the processes which cause a depletion of the ozone layer, there is, at the same time, a strong need to find viable alternatives to the use of CFCs, e.g., Freon™* -11 as blowing agents.</description><issn>1097-1963</issn><issn>0148-8287</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><recordid>eNp9j0FLxDAUhHNQcF39A57yB-rmJWmaHKW4rrCiyHouaZq0XdpmSdrD_ntb1tuCh-HBDN9jBqEnIM8AWbYBojJQgilCgM8i8gatFjNZ3Dt0H-OREApcyBXKc9-fptEG_OEr23XtUGPv8M7qER-CHqKbo7EJfqob_N3WbYW_fHeegh0bPVi89bp_QLdOd9E-_t01-tm-HvJdsv98e89f9omhhI6JlErLEgRIIbgSwDJGWGnSzJbClIqD487KqpSp05YZQ1NHTaUFM5QDVIKtEb38NcHHGKwrTqHtdTgXQIplenE9fYY2Fyjq2hZHP4Vh7vgf8Qsqnlr0</recordid><startdate>199007</startdate><enddate>199007</enddate><creator>Smits, G.F.</creator><creator>Thoen, J.A.</creator><general>Sage Publications</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199007</creationdate><title>Computer Modelling of Heat Transfer through Rigid Polyurethane Foam</title><author>Smits, G.F. ; Thoen, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c202t-889a8b161866496137303bc57eb6cb941f4fe8db85fae3cc25f2cda63c2411d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Smits, G.F.</creatorcontrib><creatorcontrib>Thoen, J.A.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of thermal envelope & building science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Smits, G.F.</au><au>Thoen, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computer Modelling of Heat Transfer through Rigid Polyurethane Foam</atitle><jtitle>Journal of thermal envelope & building science</jtitle><date>1990-07</date><risdate>1990</risdate><volume>14</volume><issue>1</issue><spage>81</spage><epage>92</epage><pages>81-92</pages><issn>1097-1963</issn><issn>0148-8287</issn><abstract>In order to meet new demands for reduction in energy consumption for the appliance and building applications, there is an urgent need for the develop ment of rigid closed celled polyurethane foams with improved insulation properties. Furthermore, in view of the fact that chlorofluorocarbons (CFCs) have been iden tified as important potential contributors to the processes which cause a depletion of the ozone layer, there is, at the same time, a strong need to find viable alternatives to the use of CFCs, e.g., Freon™* -11 as blowing agents.</abstract><cop>Thousand Oaks, CA</cop><pub>Sage Publications</pub><doi>10.1177/109719639001400108</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1097-1963 |
ispartof | Journal of thermal envelope & building science, 1990-07, Vol.14 (1), p.81-92 |
issn | 1097-1963 0148-8287 |
language | eng |
recordid | cdi_crossref_primary_10_1177_109719639001400108 |
source | Access via SAGE; Alma/SFX Local Collection |
title | Computer Modelling of Heat Transfer through Rigid Polyurethane Foam |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T07%3A36%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computer%20Modelling%20of%20Heat%20Transfer%20through%20Rigid%20Polyurethane%20Foam&rft.jtitle=Journal%20of%20thermal%20envelope%20&%20building%20science&rft.au=Smits,%20G.F.&rft.date=1990-07&rft.volume=14&rft.issue=1&rft.spage=81&rft.epage=92&rft.pages=81-92&rft.issn=1097-1963&rft_id=info:doi/10.1177/109719639001400108&rft_dat=%3Csage_cross%3E10.1177_109719639001400108%3C/sage_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.1177_109719639001400108&rfr_iscdi=true |