A Novel and Robust Homogeneous Fluorescence-Based Assay Using Nanoparticles for Pharmaceutical Screening and Diagnostics

We have established a new type of homogeneous immunoassay based on nanoparticles (nanoparticle immunoassay, or NPIA) being analyzed using fluorescence intensity distribution analysis (FIDA). This method allows the characterization of single fluorescently labeled molecules or particles with respect t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomolecular screening 2000-08, Vol.5 (4), p.227-237
Hauptverfasser: Schaertl, Sabine, Meyer-Almes, Franz-Josef, Lopez-Calle, Eloisa, Siemers, Adrian, Kramer, Joachim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have established a new type of homogeneous immunoassay based on nanoparticles (nanoparticle immunoassay, or NPIA) being analyzed using fluorescence intensity distribution analysis (FIDA). This method allows the characterization of single fluorescently labeled molecules or particles with respect to their molecular brightness and concentration. Upon binding of conjugates to molecules coupled to the nanoparticle surface, the brightness of the complex scales with the number of bound conjugates. The complexes can then be distinguished accurately from free conjugate and concentrations of free and bound molecules can be determined reliably. In this study we present various examples of NPIAs where capture antibodies were linked to the nanoparticles, which were either artificial beads or bacteria. Two assay formats have been developed; first, direct labeling of the conjugate was used to quantitate free antigen through competition experiments, and second, an antigen-directed antibody was labeled to establish an assay similar to a sandwich ELISA setup. The major advantages of a NPIA are the robustness and high signal-to-noise ratio at short measurement times, as demonstrated with a miniaturized experiment in a NanocarrierTM holding a volume of 1 μl/well. In addition to the good data quality, NPIAs are straightforward to perform because they require no washing steps. NPIAs open new dimensions for high throughput pharmaceutical screening and diagnostics. Assay development times can be reduced significantly because of a simple toolbox principle that is applicable to most types of assays.
ISSN:1087-0571
2472-5552
1552-454X
DOI:10.1177/108705710000500405