Optimizing calf muscle pump function

Background The tip toe manoeuvre has been promoted as the gold standard plethysmography test for measuring calf muscle pump function. The aim was to compare the tip toe manoeuvre, dorsiflexion manoeuvre and a body weight transfer manoeuvre using the ejection fraction of air-plethysmography and evalu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Phlebology 2018-06, Vol.33 (5), p.353-360
Hauptverfasser: Lattimer, Christopher R, Franceschi, Claude, Kalodiki, Evi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The tip toe manoeuvre has been promoted as the gold standard plethysmography test for measuring calf muscle pump function. The aim was to compare the tip toe manoeuvre, dorsiflexion manoeuvre and a body weight transfer manoeuvre using the ejection fraction of air-plethysmography and evaluate which has the best pumping effect. Methods Sixty-six archived tracings on 22 legs were retrieved from an air-plethysmography workshop and analysed. Pumping performance was measured using the calf volume reduction after each manoeuvre. Results Expressed as median [inter-quartile range], body weight transfer manoeuvres resulted in a significantly greater ejection fraction (%) than tip toe manoeuvres at 59.7 [53.5–63.9] versus 42.6 [30.5–52.6], P 
ISSN:0268-3555
1758-1125
DOI:10.1177/0268355517709410