Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes
Purpose: To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. Methods: IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-...
Gespeichert in:
Veröffentlicht in: | Ophthalmic research 2006-01, Vol.38 (1), p.13-18 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 18 |
---|---|
container_issue | 1 |
container_start_page | 13 |
container_title | Ophthalmic research |
container_volume | 38 |
creator | Stoiber, Josef Fernandez, Viviana Lamar, Peggy D. Hitzl, Wolfgang Fantes, Francisco Parel, Jean-Marie |
description | Purpose: To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. Methods: IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Results: Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Conclusion: Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP. |
doi_str_mv | 10.1159/000088492 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1159_000088492</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>941829701</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-f45ee977c026b7867d5bcb572a99d2afa88432d9bbdf33be779960ae0f938dda3</originalsourceid><addsrcrecordid>eNpd0E1LxDAQBuAgirt-HDwLEjwIHqrTpE2aiyBL_YAF97CeS9qk0rVN1qRd3H9vpMsKzmVgeGYYXoQuYriL41TcQ6gsSwQ5QNM4ITQCkopDNAWgEFGe8Ak68X4FELCAYzSJWSwIT-gUPeTfeNNsLM43sh1k31iDbY2X1thooQ2WRuGF0UNn-zDqdO-2uDF4Jnucb7U_Q0e1bL0-3_VT9P6UL2cv0fzt-XX2OI8qSqGP6iTVWnBeAWElzxhXaVmVKSdSCEVkLcP3lChRlqqmtNScC8FAaqgFzZSS9BTdjHfXzn4N2vdF1_hKt6002g6-YDzlGWQswOt_cGUHZ8JvBSEJSznjENDtiCpnvXe6Ltau6aTbFjEUv4kW-0SDvdodHMpOqz-5izCAyxF8Sveh3R6M6z83r3ed</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>224657670</pqid></control><display><type>article</type><title>Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes</title><source>Karger Journals</source><source>MEDLINE</source><creator>Stoiber, Josef ; Fernandez, Viviana ; Lamar, Peggy D. ; Hitzl, Wolfgang ; Fantes, Francisco ; Parel, Jean-Marie</creator><creatorcontrib>Stoiber, Josef ; Fernandez, Viviana ; Lamar, Peggy D. ; Hitzl, Wolfgang ; Fantes, Francisco ; Parel, Jean-Marie</creatorcontrib><description>Purpose: To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. Methods: IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Results: Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Conclusion: Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP.</description><identifier>ISSN: 0030-3747</identifier><identifier>EISSN: 1423-0259</identifier><identifier>DOI: 10.1159/000088492</identifier><identifier>PMID: 16192743</identifier><language>eng</language><publisher>Basel, Switzerland: S. Karger AG</publisher><subject>Animals ; Anterior Chamber - physiology ; Cats ; Diagnosis, Computer-Assisted ; Equipment Design ; Intraocular Pressure ; Manometry ; Observer Variation ; Original Paper ; Reproducibility of Results ; Tonometry, Ocular - instrumentation ; Tonometry, Ocular - standards</subject><ispartof>Ophthalmic research, 2006-01, Vol.38 (1), p.13-18</ispartof><rights>2006 S. Karger AG, Basel</rights><rights>Copyright (c) 2006 S. Karger AG, Basel</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-f45ee977c026b7867d5bcb572a99d2afa88432d9bbdf33be779960ae0f938dda3</citedby><cites>FETCH-LOGICAL-c330t-f45ee977c026b7867d5bcb572a99d2afa88432d9bbdf33be779960ae0f938dda3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,2423,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16192743$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stoiber, Josef</creatorcontrib><creatorcontrib>Fernandez, Viviana</creatorcontrib><creatorcontrib>Lamar, Peggy D.</creatorcontrib><creatorcontrib>Hitzl, Wolfgang</creatorcontrib><creatorcontrib>Fantes, Francisco</creatorcontrib><creatorcontrib>Parel, Jean-Marie</creatorcontrib><title>Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes</title><title>Ophthalmic research</title><addtitle>Ophthalmic Res</addtitle><description>Purpose: To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. Methods: IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Results: Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Conclusion: Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP.</description><subject>Animals</subject><subject>Anterior Chamber - physiology</subject><subject>Cats</subject><subject>Diagnosis, Computer-Assisted</subject><subject>Equipment Design</subject><subject>Intraocular Pressure</subject><subject>Manometry</subject><subject>Observer Variation</subject><subject>Original Paper</subject><subject>Reproducibility of Results</subject><subject>Tonometry, Ocular - instrumentation</subject><subject>Tonometry, Ocular - standards</subject><issn>0030-3747</issn><issn>1423-0259</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>BENPR</sourceid><recordid>eNpd0E1LxDAQBuAgirt-HDwLEjwIHqrTpE2aiyBL_YAF97CeS9qk0rVN1qRd3H9vpMsKzmVgeGYYXoQuYriL41TcQ6gsSwQ5QNM4ITQCkopDNAWgEFGe8Ak68X4FELCAYzSJWSwIT-gUPeTfeNNsLM43sh1k31iDbY2X1thooQ2WRuGF0UNn-zDqdO-2uDF4Jnucb7U_Q0e1bL0-3_VT9P6UL2cv0fzt-XX2OI8qSqGP6iTVWnBeAWElzxhXaVmVKSdSCEVkLcP3lChRlqqmtNScC8FAaqgFzZSS9BTdjHfXzn4N2vdF1_hKt6002g6-YDzlGWQswOt_cGUHZ8JvBSEJSznjENDtiCpnvXe6Ltau6aTbFjEUv4kW-0SDvdodHMpOqz-5izCAyxF8Sveh3R6M6z83r3ed</recordid><startdate>20060101</startdate><enddate>20060101</enddate><creator>Stoiber, Josef</creator><creator>Fernandez, Viviana</creator><creator>Lamar, Peggy D.</creator><creator>Hitzl, Wolfgang</creator><creator>Fantes, Francisco</creator><creator>Parel, Jean-Marie</creator><general>S. Karger AG</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QL</scope><scope>7T7</scope><scope>7U9</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M7N</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20060101</creationdate><title>Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes</title><author>Stoiber, Josef ; Fernandez, Viviana ; Lamar, Peggy D. ; Hitzl, Wolfgang ; Fantes, Francisco ; Parel, Jean-Marie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-f45ee977c026b7867d5bcb572a99d2afa88432d9bbdf33be779960ae0f938dda3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Animals</topic><topic>Anterior Chamber - physiology</topic><topic>Cats</topic><topic>Diagnosis, Computer-Assisted</topic><topic>Equipment Design</topic><topic>Intraocular Pressure</topic><topic>Manometry</topic><topic>Observer Variation</topic><topic>Original Paper</topic><topic>Reproducibility of Results</topic><topic>Tonometry, Ocular - instrumentation</topic><topic>Tonometry, Ocular - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stoiber, Josef</creatorcontrib><creatorcontrib>Fernandez, Viviana</creatorcontrib><creatorcontrib>Lamar, Peggy D.</creatorcontrib><creatorcontrib>Hitzl, Wolfgang</creatorcontrib><creatorcontrib>Fantes, Francisco</creatorcontrib><creatorcontrib>Parel, Jean-Marie</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Virology and AIDS Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Ophthalmic research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stoiber, Josef</au><au>Fernandez, Viviana</au><au>Lamar, Peggy D.</au><au>Hitzl, Wolfgang</au><au>Fantes, Francisco</au><au>Parel, Jean-Marie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes</atitle><jtitle>Ophthalmic research</jtitle><addtitle>Ophthalmic Res</addtitle><date>2006-01-01</date><risdate>2006</risdate><volume>38</volume><issue>1</issue><spage>13</spage><epage>18</epage><pages>13-18</pages><issn>0030-3747</issn><eissn>1423-0259</eissn><abstract>Purpose: To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. Methods: IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Results: Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Conclusion: Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP.</abstract><cop>Basel, Switzerland</cop><pub>S. Karger AG</pub><pmid>16192743</pmid><doi>10.1159/000088492</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0030-3747 |
ispartof | Ophthalmic research, 2006-01, Vol.38 (1), p.13-18 |
issn | 0030-3747 1423-0259 |
language | eng |
recordid | cdi_crossref_primary_10_1159_000088492 |
source | Karger Journals; MEDLINE |
subjects | Animals Anterior Chamber - physiology Cats Diagnosis, Computer-Assisted Equipment Design Intraocular Pressure Manometry Observer Variation Original Paper Reproducibility of Results Tonometry, Ocular - instrumentation Tonometry, Ocular - standards |
title | Ex vivo Evaluation of Tono-Pen and Pneumotonometry in Cat Eyes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T16%3A24%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ex%20vivo%20Evaluation%20of%20Tono-Pen%20and%20Pneumotonometry%20in%20Cat%20Eyes&rft.jtitle=Ophthalmic%20research&rft.au=Stoiber,%20Josef&rft.date=2006-01-01&rft.volume=38&rft.issue=1&rft.spage=13&rft.epage=18&rft.pages=13-18&rft.issn=0030-3747&rft.eissn=1423-0259&rft_id=info:doi/10.1159/000088492&rft_dat=%3Cproquest_cross%3E941829701%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=224657670&rft_id=info:pmid/16192743&rfr_iscdi=true |