Enhancement of Impinging Jet Heat Transfer Using Two Parallel Confining Plates Mounted near Rectangular Nozzle Exit
Impinging jet heat transfer on a target plate was enhanced by using two parallel confining plates mounted between a rectangular nozzle end plate and a jet target plate. The target plate was set equal to 2, 3, 4, and 5 times the jet exit width, h, and the gap ratio of two parallel confining plates, W...
Gespeichert in:
Veröffentlicht in: | Journal of Fluids 2014-03, Vol.2014 (2014), p.1-11 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Impinging jet heat transfer on a target plate was enhanced by using two parallel confining plates mounted between a rectangular nozzle end plate and a jet target plate. The target plate was set equal to 2, 3, 4, and 5 times the jet exit width, h, and the gap ratio of two parallel confining plates, W/h, were changed from 2.7 to 8.0 only by impinging length H=5h and from 2.7 to 6.7 by H≠5h. Two confining parallel plates mounted near the jet exit produced swing-type flow under some conditions. As a result, the maximum Nusselt number attained around the stagnation point was augmented by about 50% compared to the one for normal impinging jet without the two parallel plates and then spatial mean Nusselt number was increased by about 40%. |
---|---|
ISSN: | 2356-7376 2314-6826 |