Estimation of capillary density in human skeletal muscle based on maximal oxygen consumption rates
1 Program in Biomedical Engineering and 2 Department of Physiology, University of Arizona, Tucson, Arizona 85724 Submitted 16 June 2003 ; accepted in final form 30 July 2003 A previously developed Krogh-type theoretical model was used to estimate capillary density in human skeletal muscle based on p...
Gespeichert in:
Veröffentlicht in: | American journal of physiology. Heart and circulatory physiology 2003-12, Vol.285 (6), p.H2382-H2391 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1 Program in Biomedical Engineering and 2 Department of Physiology, University of Arizona, Tucson, Arizona 85724
Submitted 16 June 2003
; accepted in final form 30 July 2003
A previously developed Krogh-type theoretical model was used to estimate capillary density in human skeletal muscle based on published measurements of oxygen consumption, arterial partial pressure of oxygen, and blood flow during maximal exercise. The model assumes that oxygen consumption in maximal exercise is limited by the ability of capillaries to deliver oxygen to tissue and is therefore strongly dependent on capillary density, defined as the number of capillaries per unit cross-sectional area of muscle. Based on an analysis of oxygen transport processes occurring at the microvascular level, the model allows estimation of the minimum number of straight, evenly spaced capillaries required to achieve a given oxygen consumption rate. Estimated capillary density values were determined from measurements of maximal oxygen consumption during knee extensor exercise and during whole body cycling, and they range from 459 to 1,468 capillaries/mm 2 . Measured capillary densities, obtained with either histochemical staining techniques or electron microscopy on quadriceps muscle biopsies from healthy subjects, are generally lower, ranging from 123 to 515 capillaries/mm 2 . This discrepancy is partly accounted for by the fact that capillary density decreases with muscle contraction and muscle biopsy samples typically are strongly contracted. The results imply that estimates of maximal oxygen transport rates based on capillary density values obtained from biopsy samples do not fully reflect the oxygen transport capacity of the capillaries in skeletal muscle.
oxygen transport; Krogh cylinder model; quadriceps muscle
Address for reprint requests and other correspondence: T. W. Secomb, Dept. of Physiology, Univ. of Arizona, Tucson AZ 85724-5051 (E-mail: secomb{at}u.arizona.edu ). |
---|---|
ISSN: | 0363-6135 1522-1539 |
DOI: | 10.1152/ajpheart.00559.2003 |