Heterogeneities of Ageing in a PEMFC Stack: Links Between Membrane Pinholes, Carbon Corrosion and End-of-Life
Through a fruitful collaboration between three academic laboratories and a proton-exchange membrane fuel cell (PEMFC) manufacturer, important insights into the origin of cell voltage losses during on-site 110-cell-PEMFC-stack long-term operation (12,860 hours i.e. 1.5 years) were provided [1]. The d...
Gespeichert in:
Veröffentlicht in: | Meeting abstracts (Electrochemical Society) 2015-04, Vol.MA2015-01 (26), p.1541-1541 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Through a fruitful collaboration between three academic laboratories and a proton-exchange membrane fuel cell (PEMFC) manufacturer, important insights into the origin of cell voltage losses during on-site 110-cell-PEMFC-stack long-term operation (12,860 hours
i.e.
1.5 years) were provided [1]. The decline of the electrical performance is heterogeneous at the stack and the membrane-electrode assembly (MEA) scales, as shown by the monitoring of individual cell voltages during the aging process and segmented cell characterizations at the end-of-life. The long-term electrical performance losses were bridged to the degradation of the MEA constitutive materials. They mostly originate from the emergence of large size holes in the proton exchange membrane (PEM), which lead to detrimental hydrogen crossover. The hydrogen crossover in turn causes the formation of radical species that actively participate in the irreversible corrosion of the high-surface area carbon support in the cathode region neighboring the hole. The degradation of the carbon support further prevents the efficient access of the reactive gases and the proper removal of the reaction products. Depending on the size of the hole in the membrane, the localized loss of electrical performance may extend to the whole MEA, and depreciate its global performance (Figure 1).
This work was financially supported by Oseo-AII through the H2E project.
References
[1] L. Dubau, L. Castanheira, M. Chatenet,
F. Maillard, J. Dillet, O. Lottin, G. De Moor, C. Bas, L. Flandin, E. Rossinot, N. Caqué, “Carbon corrosion induced by membrane failure: the weak link of PEMFC long term performance”,
Int J. Hydrogen Energy,
39 (2014) 21902.
Figure 1 |
---|---|
ISSN: | 2151-2043 2151-2035 |