RF Attenuation Characteristics for In Vivo Wireless Healthcare Chip

We investigate a wireless communication system for an in vivo healthcare chip. In this paper, we present measured attenuation characteristics through the human body at several frequencies. In the measurement, we use physiological saline and fresh meat instead of a real human body. From the measured...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Applied Physics 2005-07, Vol.44 (7R), p.5275
Hauptverfasser: Yamada, Tomohiro, Uezono, Takumi, Okada, Kenichi, Masu, Kazuya, Oki, Akio, Horiike, Yasuhiro
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We investigate a wireless communication system for an in vivo healthcare chip. In this paper, we present measured attenuation characteristics through the human body at several frequencies. In the measurement, we use physiological saline and fresh meat instead of a real human body. From the measured results, we found that 13.56 MHz has an attenuation of 47 dB and is suitable for the proposed system.