Mechanisms of the mass transfer of “Loose” corrosion deposits in primary circuits of a water-cooled reactor and practical recommendations

s This paper describes the mechanisms of the mass transfer of “loose” corrosion deposits in the primary circuits of water-cooled reactors. The revealed “peaks” of the amount of suspended corrosion particles in the reactor transients are reported are reported. Two ways of using this effect are sugges...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiochemistry (New York, N.Y.) N.Y.), 2010-12, Vol.52 (6), p.596-599
Hauptverfasser: Orlenkov, I. S., Moskvin, L. N., Gusev, B. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:s This paper describes the mechanisms of the mass transfer of “loose” corrosion deposits in the primary circuits of water-cooled reactors. The revealed “peaks” of the amount of suspended corrosion particles in the reactor transients are reported are reported. Two ways of using this effect are suggested: first, for monitoring the amount of suspended corrosion particles in the circuit and the thickness of their deposits formed on the surfaces of the primary circuit equipment; second, for removing “loose” deposits containing radionuclides from primary circuits, i.e., for “non-chemical decontamination technology.”
ISSN:1066-3622
1608-3288
DOI:10.1134/S1066362210060068