Sensitivity of Liquid-Filled, End-Capped, Cylindrical, Ceramic Hydrophones

A theoretical expression is developed for the sensitivity of liquid-filled, cylindrical, ceramic hydrophones having rigid and semirigid end caps. The theory gives good agreement with experimental measurements on a lead zirconate-titanate hydrophone with two end-cap conditions and three different enc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 1964-04, Vol.36 (4), p.695-696
1. Verfasser: McMahon, G. W.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A theoretical expression is developed for the sensitivity of liquid-filled, cylindrical, ceramic hydrophones having rigid and semirigid end caps. The theory gives good agreement with experimental measurements on a lead zirconate-titanate hydrophone with two end-cap conditions and three different enclosed fluids.