SU‐FF‐J‐38: Evaluation of Positioning for Head and Neck Patients Using 2D and 3D Image Guidance

Purpose: To determine and compare reduction of setup error by two‐dimensional (2D) and three‐dimensional (3D) image guidance for radiation therapy of head and neck cancer (H&N) patients immobilized by customized masks. Methods and materials: Ten patients, immobilized with custom thermoplastic ma...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2009-06, Vol.36 (6), p.2484-2484
Hauptverfasser: Kang, H, Lovelock, D, Yorke, E, Kriminski, S, Lee, N, Amols, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: To determine and compare reduction of setup error by two‐dimensional (2D) and three‐dimensional (3D) image guidance for radiation therapy of head and neck cancer (H&N) patients immobilized by customized masks. Methods and materials: Ten patients, immobilized with custom thermoplastic masks, received weekly imaging sessions throughout treatment. A patient was first set up by matching lasers to surface marks (conventional) and then translationally corrected using manual registration of orthogonal kilovoltage radiographs with DRRs (2D/2D). A cone‐beam CT (CBCT) was acquired and manually registered to the simulation CT to determine further translational corrections (3D/3D‐manual). The registration structures were in‐field bony anatomy. A post‐treatment CBCT was acquired to assess intrafraction motion. We retrospectively evaluated the conventional, 2D/2D and 3D/3D‐manual setup with an in‐house automatic 3D/3D rigid‐body registration algorithm using translations‐only (3 degrees of freedom, DOF) and translations plus rotations (6 DOF). 56 treatment sessions (2–7 per patient) were analyzed. Results: Averaged over all sessions, 2D/2D registration led to translational corrections from conventional setup of magnitude 4±2 mm, range (0–8 mm). The addition of 3D/3D‐manual registration resulted in only small incremental adjustment (1±2 mm). For nine patients, the automatic 3 DOF registration agreed well with the final pre‐treatment position (overall 2±1 mm, range 1–7 mm). One patient showed significant differences (8±3 mm, range 4–12 mm); a loose‐fitting mask and resulting anatomical deformation were noted. However, the impact on dose even for this patient was minimal. For all patients, rotations determined by the 6 DOF registration of in‐field bony anatomy were < 4° around any axis. Intra‐fraction motion was < 2 mm and < 2° for all sessions. Conclusions: Manual 2D/2D registration of in‐field bony anatomy reduces positioning errors for mask‐immobilized H&N patients in most cases, and is easily implemented. 3D registration adds little improvement.
ISSN:0094-2405
2473-4209
DOI:10.1118/1.3181330