Multi-Lead Direct Current Potential Drop Method for In Situ Health Monitoring of Ceramic Matrix Composites

The method of direct current potential drop (DCPD) can be utilized as an effective and convenient approach for in situ damage detection, and as a nondestructive evaluation technique. We present the results from use of a multiprobe DCPD technique for in situ damage detection in loading of a SiC/SiC c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of engineering for gas turbines and power 2019-03, Vol.141 (3)
Hauptverfasser: Singh, Yogesh P, Presby, Michael J, Kannan, Manigandan, Morscher, Gregory N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The method of direct current potential drop (DCPD) can be utilized as an effective and convenient approach for in situ damage detection, and as a nondestructive evaluation technique. We present the results from use of a multiprobe DCPD technique for in situ damage detection in loading of a SiC/SiC composite. It is shown that in three different modes of loading (monotonic, fatigue, and cyclic load–unload), the sensing capabilities of DCPD technique compare well to the techniques of modal acoustic emission (AE) and digital image correlation (DIC). It was also found that DCPD technique provides a far earlier warning of failure under fatigue loading than the other two methods. In addition, we show that strategically placed multiple voltage leads on the specimen surface provide a promising way of qualitatively determining the crack initiation site. Therefore, the use of multiple lead DCPD method, together with other techniques, provides a viable option for sensing damage in ceramic matrix composites (CMCs) with complex geometries, and for applications at higher temperatures.
ISSN:0742-4795
1528-8919
DOI:10.1115/1.4041271