Discussion of Tag Gas Method Using in China Experimental Fast Reactor for Failed Fuel Assembly Location
As the first fast reactor of China, the safety of China Experimental Fast Reactor (CEFR) is extremely important, and will decide the future of Chinese fast reactor project. The fuel failure detection system of CEFR provides surveillance and protection for the first barrier-fuel cladding of CEFR, so...
Gespeichert in:
Veröffentlicht in: | Journal of nuclear engineering and radiation science 2018-10, Vol.4 (4) |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | As the first fast reactor of China, the safety of China Experimental Fast Reactor (CEFR) is extremely important, and will decide the future of Chinese fast reactor project. The fuel failure detection system of CEFR provides surveillance and protection for the first barrier-fuel cladding of CEFR, so it is one of the most important systems for the safety of CEFR. As tag gas method is an important method for fuel-failure location in fast reactor, CEFR has a medium-term and long-term plan of using this method to locating failed fuel assemblies. This paper introduces the main principle of tag gas method, summarizes the application of this method, and compares the advantages and disadvantages of each fuel failure location method. Combining the design characteristics of CEFR, this work analyzes the selection principle of tag gas isotopes and the effects on heat transfer capability of fuel element while tag gas filled in. Meanwhile, according to the detection ability of mass spectrometer and the foreign advanced utilization experiences of tag gas method, some suggestions are provided. |
---|---|
ISSN: | 2332-8983 2332-8975 |
DOI: | 10.1115/1.4040029 |