Transient Response of a Short-Length (L/D = 0.2) Open-Ends Elastically Supported Squeeze Film Damper: Centered and Largely Off-Centered Whirl Motions

Commonly employed in air breathing (gas turbine) engines, squeeze film dampers (SFDs) reduce the amplitude of rotor vibration while traversing system critical speeds or in transient events such as during a maneuver load, a hard landing, a blade loss, or an engine startup/shutdown sequence that could...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of engineering for gas turbines and power 2016-12, Vol.138 (12)
Hauptverfasser: San Andrés, Luis, Den, Sean, Jeung, Sung-Hwa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Commonly employed in air breathing (gas turbine) engines, squeeze film dampers (SFDs) reduce the amplitude of rotor vibration while traversing system critical speeds or in transient events such as during a maneuver load, a hard landing, a blade loss, or an engine startup/shutdown sequence that could instantaneously shift a damper journal eccentricity (es) to near its clearance (c). Experiments investigate the dynamic force performance of an open ends, short-length (L/D = 0.2) SFD test rig with radial clearance c = 267 μm and undergoing centered (es/c = 0) to largely off-centered (es/c → 1) whirl orbit motions induced by both a large static load plus a dynamic load. Four rods, symmetrically arranged to resemble a squirrel cage, elastically support the SFD test rig. A hydraulic load system displaces the test damper structure into static eccentricity (es/c). One of two types of dynamic load with amplitude FX = FY excite the SFD: a single-frequency, stepping from low frequency to high frequency discretely; or a sine-sweep frequency growing linearly with time at 6 Hz/s, 33 Hz/s, 40 Hz/s, or 55 Hz/s. For motions departing from es/c = 0.0, 0.95, and 0.99, the dynamic load uses a sine-sweep frequency varying from 5 Hz to 245 Hz and evolving rapidly at ∼33 Hz/s. Measurements of SFD displacements characterize the behavior of the SFD rig during its transient response which crosses two system natural frequencies. For motions departing from a largely off-centered condition (es → c), the dynamic load forces the damper to whirl with highly elliptical orbits, in particular while crossing a resonance (damped natural frequency). Moreover, the dynamic motions departing from es ∼ c are smaller in amplitude than those arising from a centered condition (es/c = 0). The larger damping produced by a very small squeeze film thickness explains the difference in response amplitude. At a largely off-centered condition (es/c = 0.99) and a low excitation frequency (f 
ISSN:0742-4795
1528-8919
DOI:10.1115/1.4034002