Development of Cardiac Phased Array With Large-Size PZN-5.5 %PT Single Crystals
In recent years, the manufacturing process of lead zinc niobate-lead titanate [Pb(Zn 1/3 Nb 2/3 )O 3 -PbTiO 3 , also called PZN-PT], has been enhanced with improvements in size, consistency, and a suitable compromise between piezoelectric properties and phase transition temperature, which means that...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2022-02, Vol.69 (2), p.744-750 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In recent years, the manufacturing process of lead zinc niobate-lead titanate [Pb(Zn 1/3 Nb 2/3 )O 3 -PbTiO 3 , also called PZN-PT], has been enhanced with improvements in size, consistency, and a suitable compromise between piezoelectric properties and phase transition temperature, which means that it is possible to obtain PZN-PT single crystals in sufficient size for performance characterization studies and batch manufacturing to produce high-performance medical ultrasonic transducers. This article mainly focuses on the development of the 64-element phased array ultrasonic transducer based on novel large-size PZN-PT piezoelectric single crystals. The composition of the single crystal was chosen as PZN-5.5 %PT. The designed center frequency of the phased array is 3.0 MHz, which is suitable for cardiac ultrasound imaging. The array elements were spaced at a 0.254-mm pitch, and interconnected through a custom-designed flexible circuit. Double matching layers with a light backing structure were applied in the transducer fabrication process to improve the performance of the array. The test results of the developed phased array showed a center frequency of 3.0 MHz, and an average -6 dB fractional bandwidth of 72%. In the vicinity of the center frequency, the two-way insertion loss (IL) was about −46 dB, while a crosstalk between the adjacent elements was less than −31 dB. The wire phantom can be distinctly imaged with the phased array, and the axial and lateral resolutions were measured to be 660 and 1299 \mu \text{m} , respectively. The image of a standard phantom was acquired to present the imaging performance of the transducer. The final results indicate that the transducer arrays based on novel large-size PZN-PT single crystals are quite promising for use in medical ultrasound imaging applications. |
---|---|
ISSN: | 0885-3010 1525-8955 |
DOI: | 10.1109/TUFFC.2021.3120774 |