Thermal problems caused by harmonic frequency leakage fluxes in three-phase, three-winding converter transformers

Harmonic frequency leakage flux can be a limiting factor in three-phase, three-winding HVDC converter transformers. Investigation of a three-phase, three-winding 240-MVA converter transformer failure indicated the failure was caused by harmonic fluxes. Calculations indicated that the magnitudes of t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power delivery 2004-01, Vol.19 (1), p.208-213
Hauptverfasser: Forrest, J.A.C., Allard, B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Harmonic frequency leakage flux can be a limiting factor in three-phase, three-winding HVDC converter transformers. Investigation of a three-phase, three-winding 240-MVA converter transformer failure indicated the failure was caused by harmonic fluxes. Calculations indicated that the magnitudes of these harmonic fluxes to be approximately 45% of the power frequency leakage flux for the transformer, and are little affected by the transformer impedance or the converter firing angle. A study of the failed transformer loading during its life was made and a calculation made of the hot spot temperature considering various insulation half-life factors. Based on published information on insulation half-life factors it was estimated that at full load the hot spot temperature of the transformer was about 159/spl deg/C. From examination of the insulation in the hot spot area, this estimate of hot spot temperature was considered reasonable.
ISSN:0885-8977
1937-4208
DOI:10.1109/TPWRD.2003.820223