Radiation Power of a Short High-Current Vacuum Arc at High Current Densities

The radiation of a vacuum arc was measured in the spectral region 200~\text {nm} \le \lambda \le 1100 nm. The arc was initiated in the center of the cathode by breaking the current in the auxiliary circuit and was fed by the rectangular current pulse with a duration of 10 ms. The interelectrode ga...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on plasma science 2022-09, Vol.50 (9), p.2729-2735
Hauptverfasser: Barinov, Yury A., Zabello, Konstantin K., Logachev, Alexander A., Poluyanova, Irina N., Sherstnev, E. V., Bogdanov, Alexander A., Shkol'nik, Sergey M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The radiation of a vacuum arc was measured in the spectral region 200~\text {nm} \le \lambda \le 1100 nm. The arc was initiated in the center of the cathode by breaking the current in the auxiliary circuit and was fed by the rectangular current pulse with a duration of 10 ms. The interelectrode gap was fixed at h = 4 mm, and the butt 2r =30 -mm CuCr30 electrodes were used. The arc was stabilized by an external uniform axial magnetic field (AMF). The radiation was coming out of the vacuum chamber through quartz ultraviolet (KU)-1 quartz window. The radiation detector was a silicon photodiode with a diameter of d =1.2 mm. It was located on an axis intersecting the axis of symmetry of the discharge in the center of the interelectrode gap. The distance from the diode to the axis of symmetry was L =1340 mm. After amplification, the signal from the diode was recorded on an oscilloscope. The measurements were made in a range of currents from 10 to 25 kA in order to cover the modes with the anodic activity. It was found that under the conditions of these experiments, the anode activity begins to manifest itself at the end of the pulse, starting with currents exceeding 15 kA. As the current increases, the activity begins closer to the beginning of the pulse. Considering the type of the spectral sensitivity of the diode, two series of measurements were made-measurements without a filter and through a yellow filter ZhS-10 that cuts off radiation with \lambda \le400 nm. The results obtained made it possible to analyze the dependence of the radiation power on the arc current. The results showed that at high current densities in the developed vacuum arc with anodic activity, a significant part of the power is transferred by radiation. At the end of a pulse with a current of \approx 25 kA, the radiation power is P_{\mathrm {uv}}~\approx ~150 kW, while in the discharge,
ISSN:0093-3813
1939-9375
DOI:10.1109/TPS.2022.3175577