A Cascaded Bridgeless Boost PFC With Low Common-Mode Noise

The conventional bridgeless boost power factor correction (PFC) rectifier is a "paralleled" type bridgeless PFC structure. Although it has the advantages of small on -state loss, least number of components, and no bridge-arm pass-through risk, it cannot be directly used in industrial produ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2024-05, Vol.39 (5), p.4969-4973
Hauptverfasser: He, Yuanbin, Hu, Jinsheng, Shen, Chenyu, Hang, Lijun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The conventional bridgeless boost power factor correction (PFC) rectifier is a "paralleled" type bridgeless PFC structure. Although it has the advantages of small on -state loss, least number of components, and no bridge-arm pass-through risk, it cannot be directly used in industrial products due to serious common-mode noise problems. In order to solve this issue, the letter proposes a "cascaded" bridgeless boost PFC with single inductor, two sets of bus capacitors, and common ground between the ac and dc sides. The total bus capacitance value is the same with that of paralleled bridgeless PFC when the PFC is used as a prestage circuit. A lab-scale experimental prototype is developed to validate the effectiveness of the proposed cascaded bridgeless topology on suppressing the common-mode noise interference.
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2024.3356588