Medium Voltage Soft-Switching DC/DC Converter With Series-Connected SiC MOSFETs

Nowadays, due to the growing demands of data centers, the traditional line frequency transformer based data center power distribution system (DC-PDS) is becoming bulky and inefficient. Although SST-based DC-PDS dramatically improves the system efficiency, the traditional multicell SST with input-ser...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2021-02, Vol.36 (2), p.1451-1462
Hauptverfasser: Lu, Zhebie, Li, Chengmin, Zhu, Ankang, Luo, Haoze, Li, Chushan, Li, Wuhua, He, Xiangning
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nowadays, due to the growing demands of data centers, the traditional line frequency transformer based data center power distribution system (DC-PDS) is becoming bulky and inefficient. Although SST-based DC-PDS dramatically improves the system efficiency, the traditional multicell SST with input-series output-parallel architectures has limitations. Using high-voltage devices to develop single-cell SST improves system performance, however, its application is limited by high-voltage power devices. As an alternative solution, achieving high blocking voltage through the series connection of low-voltage devices brings several advantages. Nevertheless, the series connection brings about two main problems, namely the voltage imbalance among devices and the increment of switching loss. This article proposes a medium voltage series resonant converter (MVSRC) with series-connected SiC MOSFETs. By adding snubber capacitor to each SiC MOSFET and working at LLC resonant soft-switching mode, the voltage imbalance is reduced and switching loss is decreased. Due to snubber capacitors, there are differences between MVSRC and traditional LLC converter, hence the analytical model of MVSRC is established. Moreover, the voltage imbalance model is established and the voltage imbalance sensitivity is defined to guide the snubber parameter selections. Then, a design example of the 99% efficient 5-kV/400-V prototype is presented. Last, the experimental results show that the voltage imbalance is reduced effectively and the switching loss is decreased dramatically, verifying the validity of proposed methods and the accuracy of analysis.
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2020.3007225