Safe Startup Method for Zero-Voltage-Switching MOSFET Grid Inverter

Zero-voltage-switching (ZVS) mosfet grid inverter has distinct advantages such as higher efficiency and higher power density. However, the ZVS inverter may lose ZVS condition during startup stage if it does not start properly. It may increase the voltage stress on mosfets and even destroy the power...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2019-09, Vol.34 (9), p.8749-8761
Hauptverfasser: Chen, Min, Xi, Jiangbei, Chen, Yenan, Xu, Dehong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Zero-voltage-switching (ZVS) mosfet grid inverter has distinct advantages such as higher efficiency and higher power density. However, the ZVS inverter may lose ZVS condition during startup stage if it does not start properly. It may increase the voltage stress on mosfets and even destroy the power semiconductor device. In order to achieve the ZVS condition for ZVS inverter during the startup stage, this paper proposes a safe startup method with an auxiliary clamping capacitor pre-charging circuit and designed ZVS pre-charging pulse sequence. The pre-charging circuit is enabled only at the startup stage. Theoretical analysis shows that the proposed method is capable of reducing the voltage stress during the startup stage for the ZVS inverter. Finally, the proposed safe startup method is verified on a 3 kW grid inverter.
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2018.2888539