EMI Filter Volume Minimization of a Three-Phase, Three-Level T-Type PWM Converter System

In this study, the power density of a two-stage, i.e., LCLCL, electromagnetic interference (EMI) filter for a 10 kW three-phase, T-type three-level, boost-type PWM rectifier system is optimized concerning construction volume. It is found that reasonable boundary conditions limit or define most compo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2017-04, Vol.32 (4), p.2473-2480
Hauptverfasser: Boillat, David Olivier, Krismer, Florian, Kolar, Johann Walter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, the power density of a two-stage, i.e., LCLCL, electromagnetic interference (EMI) filter for a 10 kW three-phase, T-type three-level, boost-type PWM rectifier system is optimized concerning construction volume. It is found that reasonable boundary conditions limit or define most component values and only few degrees of freedom are remaining. In this context, the ratio of the first filter stage's common to differential mode inductance, k L = L cm,1 /L dm,1 , is identified to particularly affect the total filter volume. For given switching frequency and DC-link voltage of f s = 48 kHz and V dc = 700 V, a flat minimum of the overall filter volume results for 10
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2016.2617085