EMI Filter Volume Minimization of a Three-Phase, Three-Level T-Type PWM Converter System
In this study, the power density of a two-stage, i.e., LCLCL, electromagnetic interference (EMI) filter for a 10 kW three-phase, T-type three-level, boost-type PWM rectifier system is optimized concerning construction volume. It is found that reasonable boundary conditions limit or define most compo...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2017-04, Vol.32 (4), p.2473-2480 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, the power density of a two-stage, i.e., LCLCL, electromagnetic interference (EMI) filter for a 10 kW three-phase, T-type three-level, boost-type PWM rectifier system is optimized concerning construction volume. It is found that reasonable boundary conditions limit or define most component values and only few degrees of freedom are remaining. In this context, the ratio of the first filter stage's common to differential mode inductance, k L = L cm,1 /L dm,1 , is identified to particularly affect the total filter volume. For given switching frequency and DC-link voltage of f s = 48 kHz and V dc = 700 V, a flat minimum of the overall filter volume results for 10 |
---|---|
ISSN: | 0885-8993 1941-0107 |