Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points

The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minim...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2014-10, Vol.29 (10), p.5406-5416
Hauptverfasser: Hang Seng Che, Duran, Mario J., Levi, Emil, Jones, Martin, Wooi-Ping Hew, Abd Rahim, Nasrudin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype.
ISSN:0885-8993
1941-0107
DOI:10.1109/TPEL.2013.2293195