Characteristics of Large Area CCD Imaging Systems
A review is presented of rear-illuminated CCD imagers having 400 × 400 resolution elements fabricated with a double level anodized aluminum electrode system. The application of these imagers is to deep space photography where array data rates of 10KHz are required and an operating temperature of -40...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 1977-01, Vol.24 (1), p.497-500 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A review is presented of rear-illuminated CCD imagers having 400 × 400 resolution elements fabricated with a double level anodized aluminum electrode system. The application of these imagers is to deep space photography where array data rates of 10KHz are required and an operating temperature of -40°C is possible. The performance of the 400 × 400 will be discussed and comparisons made to the operating parameters of a smaller 160 × 100 array fabricated with the same technology. Finally, a review of effects of gamma radiation on device performance will be presented. |
---|---|
ISSN: | 0018-9499 1558-1578 |
DOI: | 10.1109/TNS.1977.4328731 |