Influence of Crystal Orientation on Magnetic Properties in 3% Silicon Steel With Ultra-High Tension TiN Coating

The influence of the tile angle of the [001] out of crystal surface β on iron loss improvement of 3% Si steel single crystals was investigated. This iron loss improvement was caused by tensile stress effect of TiN coating and domain refinement. When β angle was less than 3 degrees, both eddy current...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 2012-04, Vol.48 (4), p.1469-1472
Hauptverfasser: Shingaki, Y., Okabe, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The influence of the tile angle of the [001] out of crystal surface β on iron loss improvement of 3% Si steel single crystals was investigated. This iron loss improvement was caused by tensile stress effect of TiN coating and domain refinement. When β angle was less than 3 degrees, both eddy current loss and hysteresis loss decrease. Extremely low iron loss was obtained, when β angle equal to about 2 degrees. On the other hand, when β angle is more than 3 degrees, the hysteresis loss increased though the eddy current loss decreased by TiN coating. As a result, change in iron loss was small after TiN coating and domain refining. Therefore, it was clarified that the iron loss improving methods, such as domain refining and ultra-high tension coating, were effective especially in grain oriented electrical steel whose β angle is less than 3 degrees.
ISSN:0018-9464
1941-0069
DOI:10.1109/TMAG.2011.2173925