A Model For Permanent Magnet Synchronous Machines With Demagnetization Faults

An analytical model for permanent magnet synchronous machines with demagnetization faults is proposed. Using this model, the effects of fault on the induced EMF for different winding configurations are analyzed. The results are validated for two winding configurations by a finite element model. Fina...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista IEEE América Latina 2013-02, Vol.11 (1), p.414-420
Hauptverfasser: Ruschetti, C. R., Verucchi, C. J., Bossio, G. R., Garcia, G. O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An analytical model for permanent magnet synchronous machines with demagnetization faults is proposed. Using this model, the effects of fault on the induced EMF for different winding configurations are analyzed. The results are validated for two winding configurations by a finite element model. Finally, experimental results for a machine with demagnetization are presented to validate the proposal.
ISSN:1548-0992
1548-0992
DOI:10.1109/TLA.2013.6502839