SPIE-DIR: Self-Prior Information Enhanced Deep Iterative Reconstruction using Two Complementary Limited-Angle Scans for DECT

Dual-energy computed tomography (DECT) can simultaneously provide the anatomical structure and the material-specific information of the scanned object, having many applications in industry and medicine. Different from conventional CT, DECT acquires two attenuation measurements of the same object at...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2023-01, Vol.72, p.1-1
Hauptverfasser: Zhang, Yikun, Hu, Dianlin, Lyu, Tianling, Quan, Guotao, Xiang, Jun, Coatrieux, Gouenou, Luo, Shouhua, Chen, Yang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Dual-energy computed tomography (DECT) can simultaneously provide the anatomical structure and the material-specific information of the scanned object, having many applications in industry and medicine. Different from conventional CT, DECT acquires two attenuation measurements of the same object at two different x-ray spectra, resulting in apparent redundant information. This paper exploits this kind of redundancy to develop the Self-Prior Information Enhanced Deep Iterative Reconstruction (SPIE-DIR) algorithm for limited-angle DECT. Unlike the routine practice in model-based deep learning algorithms, the SPIE-DIR method simultaneously performs constraints in the projection, residual, and image domains, corresponding to three modules: projection inpainting, residual correction, and image refinement. During this stage, the prior image and prior projection derived from two complementary limited-angle scans are utilized to improve the algorithm performance. Besides, to avoid the blurring effect caused by minimizing the Euclidean distance, the Wasserstein generative adversarial network with gradient penalty is adopted to enhance the visual perception of the generated results. Experiments on the simulated data and real rat data have demonstrated that the proposed SPIE-DIR algorithm has the potential to obtain high-quality DECT images from two limited-angle scans. Furthermore, visual and quantitative assessments have shown the promising performance of SPIE-DIR in artifact removal, structural fidelity, CT number preservation, and visual perception enhancement.
ISSN:0018-9456
1557-9662
DOI:10.1109/TIM.2022.3227549