Errors in Sampled Data Phase Measurement
Synchronous real-time sampling can be used to measure the phase angle ϕ between two sine waves in a relatively low-frequency range. The data samples are acquired by a microcomputer-based system, then manipulated to determine ϕ. The system uses less hardware than a traditional phase meter, however th...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on instrumentation and measurement 1985-12, Vol.IM-34 (4), p.507-509 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Synchronous real-time sampling can be used to measure the phase angle ϕ between two sine waves in a relatively low-frequency range. The data samples are acquired by a microcomputer-based system, then manipulated to determine ϕ. The system uses less hardware than a traditional phase meter, however there will be an error in ϕ due to mislocating the zero-crossings of the two sine waves. An error analysis is given, which indicates that errors mainly depend on signal amplitudes, number of quantization bits, and number of samples per cycle. Also, numerical results are illustrated. |
---|---|
ISSN: | 0018-9456 1557-9662 |
DOI: | 10.1109/TIM.1985.4315392 |