Open-Circuit Radial Stray Magnetic Flux Density Based Noninvasive Diagnosis for Mixed Eccentricity Parameters of Interior Permanent Magnet Synchronous Motors in Electric Vehicles

By measuring the open-circuit radial stray magnetic flux density (RSMFD) of three spatial points, a novel diagnostic method for the eccentricity of interior permanent magnetic motors (IPMSMs) in electric vehicles is proposed. Outperforming traditional methods, the proposed method can noninvasively d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2023-02, Vol.70 (2), p.1983-1992
Hauptverfasser: Ma, Conggan, Li, Jiaming, Zhang, Nic, Bu, Feifei, Yang, Zhixin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:By measuring the open-circuit radial stray magnetic flux density (RSMFD) of three spatial points, a novel diagnostic method for the eccentricity of interior permanent magnetic motors (IPMSMs) in electric vehicles is proposed. Outperforming traditional methods, the proposed method can noninvasively diagnose not only the severities of static eccentricity (SE), dynamic eccentricity (DE), and mixed eccentricity (ME), but also the eccentricity location. In this article, diagnosis results are described through three eccentricity parameters: SE ratio, DE ratio, and SE angle. First, an analytical model of the open-circuit RSMFD of the IPMSM is proposed, with its accuracy validated by experiments. The pattern of the impact of the eccentricity parameters on the open-circuit RSMFD is analyzed to form the basis of the proposed method. Then, an eccentricity prototype motor, which can continuously emulate the eccentricity according to any listed eccentricity parameters, is developed. A test rig is built to collect the open-circuit RSMFD and validate the analytical calculation results. Finally, an eccentricity diagnostic model based on the open-circuit RSMFD is established. The diagnosis results proved the noninvasiveness, effectiveness, and viability of the proposed method.
ISSN:0278-0046
1557-9948
DOI:10.1109/TIE.2022.3165250