Detection of Capacitor Degradation in LC Filters for AC Drives

Adjustable-speed drives with regenerative pulsewidth modulation rectifiers-both voltage source rectifiers and current source rectifiers-have LC filters on their input to attenuate the high-frequency components of current and achieve reduced levels of total harmonic distortion. The capacitors used in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2015-09, Vol.51 (5), p.3822-3828
Hauptverfasser: Tallam, Rangarajan M., Kerkman, Russel J., Lukaszewski, Richard A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Adjustable-speed drives with regenerative pulsewidth modulation rectifiers-both voltage source rectifiers and current source rectifiers-have LC filters on their input to attenuate the high-frequency components of current and achieve reduced levels of total harmonic distortion. The capacitors used in these filters are predominantly of the metalized film construction and are prone to catastrophic failure. In this paper, a method is proposed for the detection of capacitor degradation and location of the faulted phase. The method uses measurements of voltages and currents-which may already be available for control purposes, for line synchronization and active damping-to detect impedance asymmetry and is impervious to input voltage unbalance.