Early Detection Technique for Stator Winding Inter-Turn Fault in BLDC Motor Using Input Impedance
This paper proposes a diagnosis technique algorithm for a brushless dc motors under a stator inter-turn fault (ITF) condition using input impedance. The algorithm has early detection and various speed-range detection advantages. To early and accurately detect the ITF, the rotating speed, input curre...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industry applications 2015-01, Vol.51 (1), p.240-247 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper proposes a diagnosis technique algorithm for a brushless dc motors under a stator inter-turn fault (ITF) condition using input impedance. The algorithm has early detection and various speed-range detection advantages. To early and accurately detect the ITF, the rotating speed, input current, voltage, resistance, and inductance must be analyzed. Therefore, we choose the input impedance as the detection factor because it includes all these factors. In this paper, the fault-detection system works without requiring a fast Fourier transform and the calculation of the negative-sequence impedance from the comparison of the measured impedance with the database impedance. The proposed technique was verified by the simulation and experiment. |
---|---|
ISSN: | 0093-9994 1939-9367 |
DOI: | 10.1109/TIA.2014.2330067 |