Anomalous Positive Point Prebreakdown Behavior in Dielectric Liquids

An experimental study was performed to determine the nature of events which lead to electrical breakdown in the normal alkanes from n-pentane to n-decane, and toluene. Disturbances prior to breakdown were rendered visibl by means of a shadowgraph optical system. Both electronically framed and high r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on electrical insulation 1984-04, Vol.EI-19 (2), p.93-100
Hauptverfasser: McKenny, P. J., McGrath, P. B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An experimental study was performed to determine the nature of events which lead to electrical breakdown in the normal alkanes from n-pentane to n-decane, and toluene. Disturbances prior to breakdown were rendered visibl by means of a shadowgraph optical system. Both electronically framed and high resolution single exposure photographs were taken during the prebreakdown period. Two distinct types of prebreakdown disturbance were observed whe using a point anode. In addition to the normally expected supersonic streamer, a new subsonic bush-like structure was recorded. Factors affecting the generation of the subsonic event were investigated, and are considered in terms of a gas phase process.
ISSN:0018-9367
1557-962X
DOI:10.1109/TEI.1984.298779