Anomalous Positive Point Prebreakdown Behavior in Dielectric Liquids
An experimental study was performed to determine the nature of events which lead to electrical breakdown in the normal alkanes from n-pentane to n-decane, and toluene. Disturbances prior to breakdown were rendered visibl by means of a shadowgraph optical system. Both electronically framed and high r...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on electrical insulation 1984-04, Vol.EI-19 (2), p.93-100 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An experimental study was performed to determine the nature of events which lead to electrical breakdown in the normal alkanes from n-pentane to n-decane, and toluene. Disturbances prior to breakdown were rendered visibl by means of a shadowgraph optical system. Both electronically framed and high resolution single exposure photographs were taken during the prebreakdown period. Two distinct types of prebreakdown disturbance were observed whe using a point anode. In addition to the normally expected supersonic streamer, a new subsonic bush-like structure was recorded. Factors affecting the generation of the subsonic event were investigated, and are considered in terms of a gas phase process. |
---|---|