A Gas Switch Triggered by a Microhollow Cathode Discharge (MHCD) Array With Lower Trigger Energy
A microhollow cathode discharge (MHCD) array was operated at atmospheric pressure with a pulse voltage of 2.5 kV supplied by a trigger circuit. Triggered by this MHCD array, a gas switch with an annular plate structure operated under a voltage of 27 kV with a fall time of 30 ns and a current of 400...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on electron devices 2013-02, Vol.60 (2), p.875-879 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A microhollow cathode discharge (MHCD) array was operated at atmospheric pressure with a pulse voltage of 2.5 kV supplied by a trigger circuit. Triggered by this MHCD array, a gas switch with an annular plate structure operated under a voltage of 27 kV with a fall time of 30 ns and a current of 400 A with a rise time of 15 ns was investigated. It is used for discharging the charge stored in a capacitor of 4 nF through a resistor of 50 Ω. The advantages of the switch are obvious: a compact trigger with lower trigger voltage. An electrical model including MHCD capacitance is built, and the simulation results agree well with the experimental results. |
---|---|
ISSN: | 0018-9383 1557-9646 |