Field and Laboratory Demonstration of a Fiber-Optic/RF Partial Discharges Monitoring System for Hydrogenerators Applications
In this paper, we present the results of a hybrid fiber-optic and RF-sensing technology for monitoring partial discharges on hydrogenerators, which can also be used for several other applications. The main advantages of the proposed system are passivity, flexibility, nonintrusive, inherently dielect...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on energy conversion 2010-09, Vol.25 (3), p.884-890 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, we present the results of a hybrid fiber-optic and RF-sensing technology for monitoring partial discharges on hydrogenerators, which can also be used for several other applications. The main advantages of the proposed system are passivity, flexibility, nonintrusive, inherently dielectric, and human and equipment risk-free. We describe the performance evaluation of the sensing system in laboratory and in field trial installed in a hydroelectric power station located in north of Brazil. |
---|---|
ISSN: | 0885-8969 1558-0059 |
DOI: | 10.1109/TEC.2010.2044507 |