Optimal actuator/sensor placement for nonlinear control of the Kuramoto-Sivashinsky equation

In this paper, we use a methodology that was recently proposed by Antoniades and Christofides (2001) to compute the optimal actuator/sensor locations for the stabilization, via nonlinear static output feedback control, of the zero solution of the Kuramoto-Sivashinsky equation (KSE) for values of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on control systems technology 2003-09, Vol.11 (5), p.737-745
Hauptverfasser: Yiming Lou, Christofides, P.D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, we use a methodology that was recently proposed by Antoniades and Christofides (2001) to compute the optimal actuator/sensor locations for the stabilization, via nonlinear static output feedback control, of the zero solution of the Kuramoto-Sivashinsky equation (KSE) for values of the instability parameter for which this solution is unstable. The theoretical results are illustrated through computer simulations of the closed-loop system using a high-order discretization of the KSE.
ISSN:1063-6536