Magnetic amplifiers with inductive D-C load
The occurrence of instabilities in magnetic amplifiers with inductive d-c load is well known. Less known, however, is the mechanism causing the instability, of which a published analysis is believed nonexistent. The purpose of this paper is to discuss the mechanics of instability qualitatively and q...
Gespeichert in:
Veröffentlicht in: | Transactions of the American Institute of Electrical Engineers. Part 1. Communication and electronics 1954-11, Vol.73 (5), p.466-475 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The occurrence of instabilities in magnetic amplifiers with inductive d-c load is well known. Less known, however, is the mechanism causing the instability, of which a published analysis is believed nonexistent. The purpose of this paper is to discuss the mechanics of instability qualitatively and quantitatively and to explain some of the means by which this instability can be averted. |
---|---|