Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo
Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Tho...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2004-06, Vol.14 (2), p.1802-1805 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1805 |
---|---|
container_issue | 2 |
container_start_page | 1802 |
container_title | IEEE transactions on applied superconductivity |
container_volume | 14 |
creator | Tominaka, T. Okuno, H. Ohnishi, J. Fukunishi, N. Ryuto, H. Ohtake, M. Ikegami, K. Goto, A. Yano, Y. |
description | Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Those cryogenic temperature sensors, Cernox/spl trade/, CGR and PtCo, at room temperature were bombarded by the intense 210 MeV proton beam at the RIKEN Accelerator Research Facility (RARF) of RIKEN. |
doi_str_mv | 10.1109/TASC.2004.831117 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_crossref_primary_10_1109_TASC_2004_831117</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1325158</ieee_id><sourcerecordid>901681508</sourcerecordid><originalsourceid>FETCH-LOGICAL-c350t-5d859bac6f0cacfb5cb1f5839cdb657aad863d8de64b1ac4c646ab7bf65004c53</originalsourceid><addsrcrecordid>eNpdkdFLwzAQxosoOKfvgi9FEF_szLVNmj6OolMZKHM-hzS9SEfXzKQF99-b0sHAp_vgfvdx910QXAOZAZD8cT3_LGYxIemMJwCQnQQToJRHMQV66jWhEPE4Ts6DC-c2hEDKUzoJ3layqmVXmzZErVF1LvRS2b35xrZWYYfbHVrZ9RZDh60z1gM6LNC25vchLBarULZV-NEV5jI407JxeHWo0-Dr-WldvETL98VrMV9GKqGki2jFaV5KxTRRUumSqhI05UmuqpLRTMqKs6TiFbK0BKlSxVImy6zUjPrrFE2mwf3ou7Pmp0fXiW3tFDaNbNH0TuQEGAdKuCdv_5Eb09vWLyfyGOIYGICHyAgpa5yzqMXO1ltp9wKIGKIVQ7RiiFaM0fqRu4OvdEo22spW1e44xyDnkKWeuxm5GhGP7WT4CU_-AD4bgUs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>921221611</pqid></control><display><type>article</type><title>Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo</title><source>IEEE Electronic Library (IEL)</source><creator>Tominaka, T. ; Okuno, H. ; Ohnishi, J. ; Fukunishi, N. ; Ryuto, H. ; Ohtake, M. ; Ikegami, K. ; Goto, A. ; Yano, Y.</creator><creatorcontrib>Tominaka, T. ; Okuno, H. ; Ohnishi, J. ; Fukunishi, N. ; Ryuto, H. ; Ohtake, M. ; Ikegami, K. ; Goto, A. ; Yano, Y.</creatorcontrib><description>Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Those cryogenic temperature sensors, Cernox/spl trade/, CGR and PtCo, at room temperature were bombarded by the intense 210 MeV proton beam at the RIKEN Accelerator Research Facility (RARF) of RIKEN.</description><identifier>ISSN: 1051-8223</identifier><identifier>EISSN: 1558-2515</identifier><identifier>DOI: 10.1109/TASC.2004.831117</identifier><identifier>CODEN: ITASE9</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Accelerators ; Coils ; Cryogenic temperature ; Cryogenics ; Cyclic accelerators and storage rings ; Cyclotrons ; Exact sciences and technology ; Experimental methods and instrumentation for elementary-particle and nuclear physics ; Magnetic sensors ; Nuclear physics ; Particle beams ; Physics ; Proton beams ; Radiation effects ; Research facilities ; Sensor phenomena and characterization ; Sensors ; Superconductivity ; Temperature measurement ; Temperature sensors ; Testing</subject><ispartof>IEEE transactions on applied superconductivity, 2004-06, Vol.14 (2), p.1802-1805</ispartof><rights>2004 INIST-CNRS</rights><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2004</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c350t-5d859bac6f0cacfb5cb1f5839cdb657aad863d8de64b1ac4c646ab7bf65004c53</citedby><cites>FETCH-LOGICAL-c350t-5d859bac6f0cacfb5cb1f5839cdb657aad863d8de64b1ac4c646ab7bf65004c53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1325158$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,792,23909,23910,25118,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1325158$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=16198174$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Tominaka, T.</creatorcontrib><creatorcontrib>Okuno, H.</creatorcontrib><creatorcontrib>Ohnishi, J.</creatorcontrib><creatorcontrib>Fukunishi, N.</creatorcontrib><creatorcontrib>Ryuto, H.</creatorcontrib><creatorcontrib>Ohtake, M.</creatorcontrib><creatorcontrib>Ikegami, K.</creatorcontrib><creatorcontrib>Goto, A.</creatorcontrib><creatorcontrib>Yano, Y.</creatorcontrib><title>Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo</title><title>IEEE transactions on applied superconductivity</title><addtitle>TASC</addtitle><description>Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Those cryogenic temperature sensors, Cernox/spl trade/, CGR and PtCo, at room temperature were bombarded by the intense 210 MeV proton beam at the RIKEN Accelerator Research Facility (RARF) of RIKEN.</description><subject>Accelerators</subject><subject>Coils</subject><subject>Cryogenic temperature</subject><subject>Cryogenics</subject><subject>Cyclic accelerators and storage rings</subject><subject>Cyclotrons</subject><subject>Exact sciences and technology</subject><subject>Experimental methods and instrumentation for elementary-particle and nuclear physics</subject><subject>Magnetic sensors</subject><subject>Nuclear physics</subject><subject>Particle beams</subject><subject>Physics</subject><subject>Proton beams</subject><subject>Radiation effects</subject><subject>Research facilities</subject><subject>Sensor phenomena and characterization</subject><subject>Sensors</subject><subject>Superconductivity</subject><subject>Temperature measurement</subject><subject>Temperature sensors</subject><subject>Testing</subject><issn>1051-8223</issn><issn>1558-2515</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkdFLwzAQxosoOKfvgi9FEF_szLVNmj6OolMZKHM-hzS9SEfXzKQF99-b0sHAp_vgfvdx910QXAOZAZD8cT3_LGYxIemMJwCQnQQToJRHMQV66jWhEPE4Ts6DC-c2hEDKUzoJ3layqmVXmzZErVF1LvRS2b35xrZWYYfbHVrZ9RZDh60z1gM6LNC25vchLBarULZV-NEV5jI407JxeHWo0-Dr-WldvETL98VrMV9GKqGki2jFaV5KxTRRUumSqhI05UmuqpLRTMqKs6TiFbK0BKlSxVImy6zUjPrrFE2mwf3ou7Pmp0fXiW3tFDaNbNH0TuQEGAdKuCdv_5Eb09vWLyfyGOIYGICHyAgpa5yzqMXO1ltp9wKIGKIVQ7RiiFaM0fqRu4OvdEo22spW1e44xyDnkKWeuxm5GhGP7WT4CU_-AD4bgUs</recordid><startdate>20040601</startdate><enddate>20040601</enddate><creator>Tominaka, T.</creator><creator>Okuno, H.</creator><creator>Ohnishi, J.</creator><creator>Fukunishi, N.</creator><creator>Ryuto, H.</creator><creator>Ohtake, M.</creator><creator>Ikegami, K.</creator><creator>Goto, A.</creator><creator>Yano, Y.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>F28</scope><scope>FR3</scope></search><sort><creationdate>20040601</creationdate><title>Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo</title><author>Tominaka, T. ; Okuno, H. ; Ohnishi, J. ; Fukunishi, N. ; Ryuto, H. ; Ohtake, M. ; Ikegami, K. ; Goto, A. ; Yano, Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c350t-5d859bac6f0cacfb5cb1f5839cdb657aad863d8de64b1ac4c646ab7bf65004c53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Accelerators</topic><topic>Coils</topic><topic>Cryogenic temperature</topic><topic>Cryogenics</topic><topic>Cyclic accelerators and storage rings</topic><topic>Cyclotrons</topic><topic>Exact sciences and technology</topic><topic>Experimental methods and instrumentation for elementary-particle and nuclear physics</topic><topic>Magnetic sensors</topic><topic>Nuclear physics</topic><topic>Particle beams</topic><topic>Physics</topic><topic>Proton beams</topic><topic>Radiation effects</topic><topic>Research facilities</topic><topic>Sensor phenomena and characterization</topic><topic>Sensors</topic><topic>Superconductivity</topic><topic>Temperature measurement</topic><topic>Temperature sensors</topic><topic>Testing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tominaka, T.</creatorcontrib><creatorcontrib>Okuno, H.</creatorcontrib><creatorcontrib>Ohnishi, J.</creatorcontrib><creatorcontrib>Fukunishi, N.</creatorcontrib><creatorcontrib>Ryuto, H.</creatorcontrib><creatorcontrib>Ohtake, M.</creatorcontrib><creatorcontrib>Ikegami, K.</creatorcontrib><creatorcontrib>Goto, A.</creatorcontrib><creatorcontrib>Yano, Y.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><jtitle>IEEE transactions on applied superconductivity</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tominaka, T.</au><au>Okuno, H.</au><au>Ohnishi, J.</au><au>Fukunishi, N.</au><au>Ryuto, H.</au><au>Ohtake, M.</au><au>Ikegami, K.</au><au>Goto, A.</au><au>Yano, Y.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo</atitle><jtitle>IEEE transactions on applied superconductivity</jtitle><stitle>TASC</stitle><date>2004-06-01</date><risdate>2004</risdate><volume>14</volume><issue>2</issue><spage>1802</spage><epage>1805</epage><pages>1802-1805</pages><issn>1051-8223</issn><eissn>1558-2515</eissn><coden>ITASE9</coden><abstract>Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Those cryogenic temperature sensors, Cernox/spl trade/, CGR and PtCo, at room temperature were bombarded by the intense 210 MeV proton beam at the RIKEN Accelerator Research Facility (RARF) of RIKEN.</abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/TASC.2004.831117</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1051-8223 |
ispartof | IEEE transactions on applied superconductivity, 2004-06, Vol.14 (2), p.1802-1805 |
issn | 1051-8223 1558-2515 |
language | eng |
recordid | cdi_crossref_primary_10_1109_TASC_2004_831117 |
source | IEEE Electronic Library (IEL) |
subjects | Accelerators Coils Cryogenic temperature Cryogenics Cyclic accelerators and storage rings Cyclotrons Exact sciences and technology Experimental methods and instrumentation for elementary-particle and nuclear physics Magnetic sensors Nuclear physics Particle beams Physics Proton beams Radiation effects Research facilities Sensor phenomena and characterization Sensors Superconductivity Temperature measurement Temperature sensors Testing |
title | Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T10%3A27%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiation%20effects%20on%20cryogenic%20temperature%20sensors%20of%20Cernox,%20CGR%20and%20PtCo&rft.jtitle=IEEE%20transactions%20on%20applied%20superconductivity&rft.au=Tominaka,%20T.&rft.date=2004-06-01&rft.volume=14&rft.issue=2&rft.spage=1802&rft.epage=1805&rft.pages=1802-1805&rft.issn=1051-8223&rft.eissn=1558-2515&rft.coden=ITASE9&rft_id=info:doi/10.1109/TASC.2004.831117&rft_dat=%3Cproquest_RIE%3E901681508%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=921221611&rft_id=info:pmid/&rft_ieee_id=1325158&rfr_iscdi=true |