Radiation effects on cryogenic temperature sensors of Cernox, CGR and PtCo
Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Tho...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2004-06, Vol.14 (2), p.1802-1805 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Irradiation tests have been carried out in view of selecting the cryogenic temperature sensors for use in the RIKEN Superconducting Ring Cyclotron (SRC). About 300 temperature sensors will be installed, and most of them will be exposed to high radiation doses during the operation of accelerator. Those cryogenic temperature sensors, Cernox/spl trade/, CGR and PtCo, at room temperature were bombarded by the intense 210 MeV proton beam at the RIKEN Accelerator Research Facility (RARF) of RIKEN. |
---|---|
ISSN: | 1051-8223 1558-2515 |