Time resolved self-defocusing in InSb at room temperature
We report a detailed study of time resolved self-defocusing in InSb at room temperature, using 3 μs long CO 2 laser pulses. We have determined that the intensity dependence of the refractive index varies as intensity to the two-thirds power. The measured values correspond to an equivalent dn/dI of -...
Gespeichert in:
Veröffentlicht in: | IEEE journal of quantum electronics 1985-01, Vol.21 (1), p.94-99 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report a detailed study of time resolved self-defocusing in InSb at room temperature, using 3 μs long CO 2 laser pulses. We have determined that the intensity dependence of the refractive index varies as intensity to the two-thirds power. The measured values correspond to an equivalent dn/dI of -0.11 cm 2 /MW at an incident intensity of 210 kW/cm 2 . |
---|---|