On the Time Domain Error Caused By the Frequency Domain Sampling Rate in a Reverberation Chamber
The time domain (TD) response of a reverberation chamber (RC) can be obtained from the inverse Fourier transform of the measured S-parameters in the frequency domain (FD). In the measurement, the FD sampling rate should be high enough; otherwise, the measured S-parameters will be uncorrelated, and t...
Gespeichert in:
Veröffentlicht in: | IEEE access 2019, Vol.7, p.78223-78227 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The time domain (TD) response of a reverberation chamber (RC) can be obtained from the inverse Fourier transform of the measured S-parameters in the frequency domain (FD). In the measurement, the FD sampling rate should be high enough; otherwise, the measured S-parameters will be uncorrelated, and the inverted TD response will be meaningless. We investigate the TD error caused by the sampling rate in the FD based on the measured S-parameters; from a statistical perspective, the empirical cumulative distribution functions of the TD errors for different FD sampling rates are also given. |
---|---|
ISSN: | 2169-3536 2169-3536 |
DOI: | 10.1109/ACCESS.2019.2921997 |