International intercomparison of horn gain at X-band
An international intercomparison of horn gain and polarization measurements at X-band has previously been completed. There were seven participating laboratories with the National Institute of Standards and Technology serving as the pilot laboratory. Two X-band pyramidal standard gain horns with a no...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on antennas and propagation 1996-10, Vol.44 (10), p.1367-1374 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An international intercomparison of horn gain and polarization measurements at X-band has previously been completed. There were seven participating laboratories with the National Institute of Standards and Technology serving as the pilot laboratory. Two X-band pyramidal standard gain horns with a nominal gain of 22 dB served as the traveling standards. Quantities measured included on-axis fixed frequency gain at 8, 10, and 12 GHz, swept frequency gain between 8-12 GHz and polarization characteristics at the three fixed frequencies. All laboratories performed the fixed frequency-gain measurements. The swept-frequency and polarization measurements were optional, with four laboratories performing swept-frequency measurements and three laboratories measuring polarization. The results of the gain measurements generally agreed within the reported uncertainties which were of the order of 0.1 dB or less. |
---|---|
ISSN: | 0018-926X 1558-2221 |
DOI: | 10.1109/8.537331 |