Planar HTS gradiometers with large baseline

We have designed an HTS single-layer planar rf double-hole gradiometer with long and well defined baseline up to 5 mm and small washer areas. We measured a gradient field resolution of about 1 pT/(cm/spl middot//spl radic/Hz) above 10 Hz in an unshielded environment. The gradiometer could be operate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 1997-06, Vol.7 (2), p.2866-2869
Hauptverfasser: Zhang, Y., Soltner, H., Krause, H.-J., Sodtke, E., Zander, W., Schubert, J., Gruneklee, M., Lomparski, D., Banzet, M., Bousack, H., Braginski, A.I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have designed an HTS single-layer planar rf double-hole gradiometer with long and well defined baseline up to 5 mm and small washer areas. We measured a gradient field resolution of about 1 pT/(cm/spl middot//spl radic/Hz) above 10 Hz in an unshielded environment. The gradiometer could be operated placed on a swinging pendulum in the geomagnetic field. This permitted a simple demonstration of a movable SQUID system. We placed a SQUID system on a scanning table and performed two-dimensional eddy-current nondestructive evaluation measurements on realistic samples.
ISSN:1051-8223
1558-2515
DOI:10.1109/77.621888