Generator and exciter parameter estimation of Fort Patrick Henry Hydro Unit 1
This paper describes the techniques employed for extraction of device parameters for a 20 MVA hydro-turbine generator in the Tennessee Valley Authority (TVA) power system. Several approaches were implemented in the extraction of parameters. Measurements on the generator were made prior, and subseque...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on electron devices 1999-12, Vol.14 (4), p.923-929 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper describes the techniques employed for extraction of device parameters for a 20 MVA hydro-turbine generator in the Tennessee Valley Authority (TVA) power system. Several approaches were implemented in the extraction of parameters. Measurements on the generator were made prior, and subsequent, to extensive rework as part of a generator upgrade project. In addition, static exciter and overall response tests on the complete system were performed after the upgrade. The identified generator parameters before and after the upgrade are compared. |
---|---|
ISSN: | 0885-8969 0018-9383 1558-0059 1557-9646 |