Frequency effects in capacitively coupled radio-frequency glow discharges: a comparison between a 2-D fluid model and experiments

The results of a 2-D fluid model for argon radiofrequency (RF) discharges in a closed cylindrical vacuum chamber are compared with experimental data from an amorphous silicon deposition reactor operated in argon. Good agreement is obtained for the relation between the DC autobias voltage and the dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE Transactions on Plasma Science 1995-08, Vol.23 (4), p.644-649
Hauptverfasser: Goedheer, W.J., Meijer, P.M., Bezemer, J., Diederick, J., Passchier, J.D.P., van Sark, W.G.J.H.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The results of a 2-D fluid model for argon radiofrequency (RF) discharges in a closed cylindrical vacuum chamber are compared with experimental data from an amorphous silicon deposition reactor operated in argon. Good agreement is obtained for the relation between the DC autobias voltage and the dissipated power in the frequency range 40-100 MHz at pressures between 10 and 60 Pa. Scaling laws are presented for the dissipated power and for the ion fluxes toward the electrodes. These quantities are expressed in the DC bias voltage, the RF excitation frequency and the background pressure. Also the uniformity of the ion fluxes is studied. The model yields a linear relation between the applied RF voltage and the DC bias voltage. This relation depends only on the geometry of the discharge chamber and shows an offset.< >
ISSN:0093-3813
1939-9375
DOI:10.1109/27.467986