Effects of cyclic pulsed operation on the coil performance in the Nb/sub 3/Sn Demo poloidal coil (DPC-EX)

The effect of cyclic pulsed operation on the coil performance was studied from the electrical and mechanical points of view in the second experiment of the Nb/sub 3/Sn Demo Poloidal Coil (DPC-EX). Current sharing temperatures, ac losses, displacements, and strains were measured before and after cycl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 1994-07, Vol.30 (4), p.2535-2538
Hauptverfasser: Nakajima, H., Sasaki, T., Ando, T., Nishi, M., Oshikiri, M., Hiyama, T., Takahashi, Y., Yoshida, K., Okuno, K., Kato, T., Sugimoto, M., Isono, T., Kawano, K., Koizumi, N., Hamada, K., Wadayama, Y., Miyake, A., Iwamoto, S., Ebisu, H., Takahashi, T., Hosono, F., Yamamoto, K., Yasukawa, Y., Tsukamoto, H., Hanawa, H., Seki, S., Wakabayashi, H., Ouchi, T., Tajiri, F., Okayama, J., Imahashi, K., Outsu, K., Takaya, Y., Kawasaki, T., Kon, Y., Tsuji, H., Takayasu, M., Turck, B., Wuchner, F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effect of cyclic pulsed operation on the coil performance was studied from the electrical and mechanical points of view in the second experiment of the Nb/sub 3/Sn Demo Poloidal Coil (DPC-EX). Current sharing temperatures, ac losses, displacements, and strains were measured before and after cyclic pulsed operation, which consisted of about 350 cycles. No degradation of the electrical and mechanical performance of the DPC-EX was observed in the range of these cycles.< >
ISSN:0018-9464
1941-0069
DOI:10.1109/20.305794