The Safety and Efficacy of Brinzolamide 1%/Timolol 0.5% Fixed Combination Versus Dorzolamide 2%/Timolol 0.5% in Patients With Open-angle Glaucoma or Ocular Hypertension

PURPOSEThis study compared the intraocular pressure (IOP)-lowering efficacy of 2 fixed combination products, brinzolamide 1%/timolol 0.5% suspension (Azarga, Brinz/Tim) and dorzolamide 2%/timolol 0.5% solution (Dorz/Tim), in patients with open-angle glaucoma or ocular hypertension who required a cha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of glaucoma 2009-04, Vol.18 (4), p.293-300
Hauptverfasser: Manni, Gianluca, Denis, Phillipe, Chew, Paul, Sharpe, Elisabeth D, Orengo-Nania, Silvia, Coote, Michael A, Laganovska, Guna, Volksone, Lasma, Zeyen, Thierry, Filatori, Isabella, James, John, Aung, Tin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSEThis study compared the intraocular pressure (IOP)-lowering efficacy of 2 fixed combination products, brinzolamide 1%/timolol 0.5% suspension (Azarga, Brinz/Tim) and dorzolamide 2%/timolol 0.5% solution (Dorz/Tim), in patients with open-angle glaucoma or ocular hypertension who required a change in therapy due to elevated IOP while receiving IOP-lowering medication. METHODSThis was a one-year, multicenter, randomized, double-masked, active-controlled, parallel-group trial of Brinz/Tim and Dorz/Tim. IOP assessments were taken at 8 and 10 AM at week 2 and months 3 and 9, and at 8 AM, 10 AM, and 4 PM at months 6 and 12. Primary efficacy was a noninferiority comparison of mean IOP at the three month 6 time points. RESULTSOf the 437 patients enrolled, 220 dosed Brinz/Tim whereas 217 dosed Dorz/Tim twice daily. Brinz/Tim produced IOP-lowering efficacy comparable to Dorz/Tim, with the upper 95% confidence limits for the differences between groups within +1.5 mm Hg at all assessment times, including the month 6 primary efficacy time points, establishing noninferiority. Differences in means numerically favored Brinz/Tim at 9 of 12 study visits and times. The IOP reductions ranged from 7.2 to 9.2 mm Hg for Brinz/Tim and from 7.4 to 8.9 mm Hg for Dorz/Tim. Although a similar overall safety profile was observed between the 2 treatment groups, Brinz/Tim showed significantly less ocular irritation (2.7% vs. 10.6%; P=0.0009) than Dorz/Tim. CONCLUSIONSBrinz/Tim suspension provides statistically significant and clinically relevant IOP-lowering efficacy that is noninferior to Dorz/Tim. Additionally, Brinz/Tim affords an ocular comfort advantage compared with Dorz/Tim.
ISSN:1057-0829
1536-481X
DOI:10.1097/IJG.0b013e31818fb434